Page 63
Appendix | Factory Settings
thermoMETER CSmicro
OUT
At 3-state output the following settings are default:
Pre-alarm difference
2 °C
No alarm level
8 V
Pre-alarm level
5 V
Alarm level
0 V
Service voltage
10 V
IN/OUT
At Alarm output (open collector) the following settings are default:
Mode
Normally closed
Temp code output
Activated (for values above alarm level)
Range settings
0 °C = 0 %/ 100 °C = 100 %
Vcc adjust
If activated the following settings are default:
Output voltage range
0 - 10 V
Difference mode
Activated
Alarm level
Alarm value (IN/ OUT pin)
Vcc
1
40 °C
11 V
2
45 °C
12 V
3
50 °C
13 V
4
55 °C
14 V
5
60 °C
15 V
6
65 °C
16 V
7
70 °C
17 V
8
75 °C
18 V
9
80 °C
19 V
10
85 °C
20 V