Page 62
Appendix | Factory Settings
thermoMETER CSmicro
Model
2W-SF15
2W-SF15H
2W-SF22H
hsSF
2WM-2L
2WM-2H
Temperature range
0 ... 350 °C
0 ... 500 °C
0 ... 500 °C
-20 ... 150 °C
250 ... 800 °C
385 ° ... 1600 °C
Output
4 ... 20 mA
4 ... 20 mA
4 ... 20 mA
4 ... 20 mA
4 ... 20 mA
4 ... 20 mA
Emissivity
0,950
0,950
0,950
0,950
0,950
0,950
Transmission
1,000
1,000
1,000
1,000
1,000
1,000
Average time
0,3 s
0,3 s
0,3 s
0,3 s
0,3 s
0,3 s
Smart Averaging
Active
Active
Active
Active
Active
Active
Smart Averaging hysteresis
2 °C
2 °C
2 °C
2 °C
2 °C
2 °C
Operating temperature source
Internal (sensor temperature)
Status-LED function
Self diagnostic
Input (IN/ OUT/ green)
Communication input
Output (OUT/ yellow)
Communication output
Vcc adjust
Inactive
Signal processing
Hold mode: off
Calibration
Gain 1,000/ Offset 0,0
Failsafe
Inactive
.
For a usage of the thermoMETER CSmicro SF for online maintenance applications (in electrical cabinets e.g.) the following recom-
mend settings are already included in the factory default setting (but not active):