NOTE: After some time, the fl exible hose may not hold in a
horizontal position. This can be fi xed by twisting the hose
counterclockwise thereby tightening the segmented joints.
OPTIONAL INSTALLATION:
A. Table Bracket Mounting (Fig. 3)
This option is designed when the customer wishes to place
the unit on the fl oor and clamp the hose to a bracket on the
table. This clears space for the worker.
B. Vertical Wall Mount Assembly (Fig. 4)
This installation allows the SC150 to be mounted on a wall
in a vertical position. The exhaust is then pointed upward,
and the arm(s) are at the bottom end, close to the work area.
The kit contains:
1 each: Wall bracket
1 each: Unit bracket
3 each: #10 x 1-1/4” hex screw
1. Remove the two plastic feet near the air exhaust end of
the SC150 using a phillips head screw driver. Retain
the screws.
2. Attach the unit bracket to the bottom of the SC150
using screws that originally secured plastic feet (Fig.
5).
3. After location of the wall mount has been decided,
install the SC150 wall bracket supplied in this kit
by mounting to the wall using the 3 #10 hex crews
provided. Noter that source capture arm is 34” long
and should be located within easy reach of work area.
CAUTION: WHEN MOUNTING THE WALL
BRACKET TO THE WALLBOARD, BE CERTAIN
THAT SCREWS ARE SECURED TO A WALL
BOARD VIA WALL JOISTS, OR BY MEANS
OF A THREADED INSERT. WALL BOARD
MATERIAL IS NOT INTEDNED TO SOELEY
HOLD WEIGHT OF THE AIR CLEANER.
4. Once the wall bracket and unit bracket are in place, lift
the SC150 and mount to the wall bracket (Fig. 4).
B. Horizontal Wall Mount Assembly (Fig. 6)
The kit contains:
2 each: Wall brackets
4 each: #10 x 1-1/4” hex screws
1 each: #8 x 1/2” self tapping screw