SPECIFICATIONS

Description of parameter

Parameter value

360-degree scanning rate, rpm

12 to 24

Range resolution, m

3

Heading resolution, maximum

Operating frequency range, MHz

9300 to 9500

Modulation period, ms

3.5

Maximum frequency deviation, MHz

100

Transceiver design

Solid state transceiver module

Output power, max, W

1

Peak-power-output adjustment, dB

0-28

Antenna polarization

Horizontal

Antenna horizontal beamwidth (a –3 dB)

Antenna vertical beamwidth (a –3 dB)

30°

Radar warm-up time, min, maximum

4

Degree of protection ensured by radar (antenna unit + rotation 

unit) housing assembly

IР65

Degree of protection ensured by the housing of communication 

unit, MFD

IР22

Power supply voltage of DC system, V

+17 to +27

Parameters of 220 VAC power supply system

- Voltage, V

- Frequency, Hz

198 to +233

47.5 to 52.5

Power consumption, W, maximum

100

Radiation type

FMCW (Frequency-Modulated Continuous Wave)

Data interface

Ethernet 100Base-T

4

Summary of Contents for MRS-1000

Page 1: ...DOCUMENT VER 1 0 AUGUST 2015 MRS 1000 RADAR SYSTEM USER MANUAL...

Page 2: ...ATION 5 SAFETY PRECAUTIONS 5 INSTALLATION AND REMOVAL 5 MAINTENANCE 5 FUSE REPLACEMENT 6 OPERATING LIMITATIONS 8 STORAGE 8 TRANSPORTATION 8 DISPOSAL 9 MANUFACTURER S WARRANTY 9 SPECIFICATIONS 10 DELIV...

Page 3: ...it MRS 1000 RU Communication cable MRS 1000 CC Indoor equipment Communication Unit MRS 1000 CU CONFIGURATION 1 CAUTION The antenna unit and rotation unit are de signed for operation under ambient air...

Page 4: ...VIEW ABOUT FREQUENCY MODULATED CONTINUOUS WAVE FMCW MRS 1000 Radar uses FMCW Frequency Modulated Continuous Wave radar technology The main distinguishing feature of broadband radar unlike traditional...

Page 5: ...NT THE ANTENNA UNIT HOUSING MAINTENANCE In normal mode the radar system requires no maintenance nor any operations by mainte nance personnel except for preventive main tenance Repair of the station is...

Page 6: ...Off switch on the rotation unit to the OFF position 3 Detach the cable from the rotation unit connector 4 Undo six M4 screws on the rotation unit cover Carefully move it aside FUSE REPLACEMENT GPS GPS...

Page 7: ...If powered from the electrical system of 220VAC 1 Set the 220VAC power switch to the OFF position 2 Detach 220VAC power connector of the electrical system CAUTION The new fuse shall comply with the fo...

Page 8: ...e premises at a tempera ture from minus 50 to plus 50 and average monthlyrelativeairhumidityof80 atplus20 A short term humidity elevation up to 98 at plus 25 without condensation is permitted pro vide...

Page 9: ...have lost their consumer properties shall be disposed of by special agencies autho rized by the government in accordance with lo cal law GENERAL INFORMATION MANUFACTURER S WARRANTY The Manufacturer gu...

Page 10: ...Antenna polarization Horizontal Antenna horizontal beamwidth a 3 dB 1 Antenna vertical beamwidth a 3 dB 30 Radar warm up time min maximum 4 Degree of protection ensured by radar antenna unit rotation...

Page 11: ...ns W H L cm Qty Antenna Unit MRS 1000 AU 10 5 200 17 15 1 Rotation Unit MRS 1000 RU 16 36 29 36 1 Communication cable MRS 1000 2 5 20 m 1 Communication Unit MRS 1000 U 3 35 19 9 1 Operating documents...

Page 12: ...s in the course of radar operation you can contact our Customer Support When making a call be ready to name your organization owning the radar and the radar model Contact information of Technical Supp...

Page 13: ...13...

Page 14: ...E mail sales micran com Phone 7 3822 900 029 7 3822 413 403 7 3822 413 406 Fax 7 3822 423 615 Mailing address Micran Kirova Ave 51d Tomsk Russia 634041 www micran com...

Reviews: