Procedure  for  Communication  Unit  Fuse  Re

-

placement

If powered from 24VDC power supply circuit:
1.  Detach 24VDC connector of the electrical 

system.

2. 

Slightly  press  the  fuse  holder  cover  and 

turn it counter-clockwise.

3. 

Remove the fuse holder.

4.  Replace the fuse with a new one.

5.  Insert the 24VDC fuse holder into the unit 

and turn it clockwise.

6. 

Attach  24VDC  connector  of  the  electrical 

system.

If powered from the electrical system of 

220VAC:
1.  Set the 220VAC power switch to the OFF 

position.

2.  Detach 220VAC power connector of the 

electrical system.

CAUTION!
The new fuse shall comply with the follow-

ing requirements:

•  Cylindrical fuse link measuring 5x20

• 

Rated current of 5 A.

CAUTION!
The new fuse shall comply with the follow-

ing requirements:

•  Cylindrical fuse link measuring 5x20

• 

Rated current of 2 A.

i

i

3. 

Remove the 220VAC fuse holder.

4.  Replace the fuse with a new one.
5.  Insert the 220VAC fuse holder into the unit.
6. 

Attach 220VAC connector of the electrical 

system.

GENERAL INFORMATION

Summary of Contents for MRS-1000

Page 1: ...DOCUMENT VER 1 0 AUGUST 2015 MRS 1000 RADAR SYSTEM USER MANUAL...

Page 2: ...ATION 5 SAFETY PRECAUTIONS 5 INSTALLATION AND REMOVAL 5 MAINTENANCE 5 FUSE REPLACEMENT 6 OPERATING LIMITATIONS 8 STORAGE 8 TRANSPORTATION 8 DISPOSAL 9 MANUFACTURER S WARRANTY 9 SPECIFICATIONS 10 DELIV...

Page 3: ...it MRS 1000 RU Communication cable MRS 1000 CC Indoor equipment Communication Unit MRS 1000 CU CONFIGURATION 1 CAUTION The antenna unit and rotation unit are de signed for operation under ambient air...

Page 4: ...VIEW ABOUT FREQUENCY MODULATED CONTINUOUS WAVE FMCW MRS 1000 Radar uses FMCW Frequency Modulated Continuous Wave radar technology The main distinguishing feature of broadband radar unlike traditional...

Page 5: ...NT THE ANTENNA UNIT HOUSING MAINTENANCE In normal mode the radar system requires no maintenance nor any operations by mainte nance personnel except for preventive main tenance Repair of the station is...

Page 6: ...Off switch on the rotation unit to the OFF position 3 Detach the cable from the rotation unit connector 4 Undo six M4 screws on the rotation unit cover Carefully move it aside FUSE REPLACEMENT GPS GPS...

Page 7: ...If powered from the electrical system of 220VAC 1 Set the 220VAC power switch to the OFF position 2 Detach 220VAC power connector of the electrical system CAUTION The new fuse shall comply with the fo...

Page 8: ...e premises at a tempera ture from minus 50 to plus 50 and average monthlyrelativeairhumidityof80 atplus20 A short term humidity elevation up to 98 at plus 25 without condensation is permitted pro vide...

Page 9: ...have lost their consumer properties shall be disposed of by special agencies autho rized by the government in accordance with lo cal law GENERAL INFORMATION MANUFACTURER S WARRANTY The Manufacturer gu...

Page 10: ...Antenna polarization Horizontal Antenna horizontal beamwidth a 3 dB 1 Antenna vertical beamwidth a 3 dB 30 Radar warm up time min maximum 4 Degree of protection ensured by radar antenna unit rotation...

Page 11: ...ns W H L cm Qty Antenna Unit MRS 1000 AU 10 5 200 17 15 1 Rotation Unit MRS 1000 RU 16 36 29 36 1 Communication cable MRS 1000 2 5 20 m 1 Communication Unit MRS 1000 U 3 35 19 9 1 Operating documents...

Page 12: ...s in the course of radar operation you can contact our Customer Support When making a call be ready to name your organization owning the radar and the radar model Contact information of Technical Supp...

Page 13: ...13...

Page 14: ...E mail sales micran com Phone 7 3822 900 029 7 3822 413 403 7 3822 413 406 Fax 7 3822 423 615 Mailing address Micran Kirova Ave 51d Tomsk Russia 634041 www micran com...

Reviews: