background image

6

The radar system is fitted with fuses to protect 

power supply circuits in the following units:

•  Rotation unit (24 V power supply circuit)
•  Communication  unit  (24  V  power  supply 

circuit and 220 V electrical system)

Procedure for Rotation Unit Fuse Replacement

1. 

De-energize  the  communication  unit  by 

setting the 220 V ON/OFF switch to the OFF 

position (if the unit supplied from 220 VAC 

electrical system) or detach the connector 

of the 24 VDC electrical system.

2. 

Set the ON/Off switch on the rotation unit 

to the OFF position.

3. 

Detach  the  cable  from  the  rotation  unit 

connector.

4. 

Undo  six  M4  screws  on  the  rotation  unit 

cover. Carefully move it aside.

FUSE REPLACEMENT

соединения, согласно 

инструкции на компас

 

Устройство не подключено

 

Анемометр

 

Проверьте 

правильность 

соединения, согласно 

инструкции на 

анемометр

 

Устройство не подключено

 

GPS 

Проверьте 

правильность 

соединения, согласно 

инструкции на 

GPS 

Устройство не подключено

 

Эхолот

 

Проверьте 

правильность 

соединения, согласно 

инструкции на эхолот

 

Устройство не подключено

 

ЛАГ

 

Проверьте 

правильность 

соединения, согласно 

инструкции на ЛАГ

 

Устройство не подключено

 

Анемометр

 

Проверьте 

правильность 

соединения, согласно 

инструкции на АИС

 

Сбой канала Тх

 

Проверьте соединения 

кабелей антенны 

 

Превышен лимит КСВН 

антенны

 

Потеряна внешняя система 

позиционирования

 

Проверьте 

подключение 

GPS 

к 

АИС в соответствии с 

эксплуатационной 

документации на эти 

устройства.

 

Отсутствует система 

позиционирования

 

Нет данных о скорости судна

 

 

Замена предохранителей

 

 

В  станции

 

предусмотрены  предохранители, для  защиты  цепей питания  в 

следующих блоках:

 

мотор

-

редукторе

 

(цепь питания 24В)

блоке сопряжения

 

(цепи питания от бортовой сети и сети 220В)

блоке управления и индикации

 

(цепи питания от бортовой сети и сети 

220В)

Методика

 

замены предохранителя в мотор

-

редукторе

 

1. 

Отключите питание на блоке сопряжения

 

переводом выключателя 

питания  220В  в  положение  «ОТКЛ»  (если  блок  запитан  от  сети 

~

220В)

 

или отключите разъем питания бортовой сети 24В

2. 

Переведите  тумблер  питания  на  мотор

-

редукторе  в  положение

 

«ОТКЛ»

3. 

Отключите кабель от разъема Мотор

-

редуктора.

 

 

4. 

Открутите шесть винтов М4 на крышке Мотор

-

редуктора. Аккурат-

но отодвиньте ее в сторону.

 

5. 

Remove the fuse from the fuse holder con

-

nector arranged on the board. Replace the 

fuse with a new one.

6. 

Close the cover and drive in six M4 screws.

7. 

Attach the cable to the connector and set 

the ON/OFF toggle switch to the ON posi-

tion.

1 – Fuse Holder

CAUTION!
The new fuse shall comply with the follow-

ing requirements:

• 

Fusible link, for cars, mini format

• 

Rated current of 7.5 A.

i

1

GENERAL INFORMATION

On/Off switch

M4 screws

Connector

Summary of Contents for MRS-1000

Page 1: ...DOCUMENT VER 1 0 AUGUST 2015 MRS 1000 RADAR SYSTEM USER MANUAL...

Page 2: ...ATION 5 SAFETY PRECAUTIONS 5 INSTALLATION AND REMOVAL 5 MAINTENANCE 5 FUSE REPLACEMENT 6 OPERATING LIMITATIONS 8 STORAGE 8 TRANSPORTATION 8 DISPOSAL 9 MANUFACTURER S WARRANTY 9 SPECIFICATIONS 10 DELIV...

Page 3: ...it MRS 1000 RU Communication cable MRS 1000 CC Indoor equipment Communication Unit MRS 1000 CU CONFIGURATION 1 CAUTION The antenna unit and rotation unit are de signed for operation under ambient air...

Page 4: ...VIEW ABOUT FREQUENCY MODULATED CONTINUOUS WAVE FMCW MRS 1000 Radar uses FMCW Frequency Modulated Continuous Wave radar technology The main distinguishing feature of broadband radar unlike traditional...

Page 5: ...NT THE ANTENNA UNIT HOUSING MAINTENANCE In normal mode the radar system requires no maintenance nor any operations by mainte nance personnel except for preventive main tenance Repair of the station is...

Page 6: ...Off switch on the rotation unit to the OFF position 3 Detach the cable from the rotation unit connector 4 Undo six M4 screws on the rotation unit cover Carefully move it aside FUSE REPLACEMENT GPS GPS...

Page 7: ...If powered from the electrical system of 220VAC 1 Set the 220VAC power switch to the OFF position 2 Detach 220VAC power connector of the electrical system CAUTION The new fuse shall comply with the fo...

Page 8: ...e premises at a tempera ture from minus 50 to plus 50 and average monthlyrelativeairhumidityof80 atplus20 A short term humidity elevation up to 98 at plus 25 without condensation is permitted pro vide...

Page 9: ...have lost their consumer properties shall be disposed of by special agencies autho rized by the government in accordance with lo cal law GENERAL INFORMATION MANUFACTURER S WARRANTY The Manufacturer gu...

Page 10: ...Antenna polarization Horizontal Antenna horizontal beamwidth a 3 dB 1 Antenna vertical beamwidth a 3 dB 30 Radar warm up time min maximum 4 Degree of protection ensured by radar antenna unit rotation...

Page 11: ...ns W H L cm Qty Antenna Unit MRS 1000 AU 10 5 200 17 15 1 Rotation Unit MRS 1000 RU 16 36 29 36 1 Communication cable MRS 1000 2 5 20 m 1 Communication Unit MRS 1000 U 3 35 19 9 1 Operating documents...

Page 12: ...s in the course of radar operation you can contact our Customer Support When making a call be ready to name your organization owning the radar and the radar model Contact information of Technical Supp...

Page 13: ...13...

Page 14: ...E mail sales micran com Phone 7 3822 900 029 7 3822 413 403 7 3822 413 406 Fax 7 3822 423 615 Mailing address Micran Kirova Ave 51d Tomsk Russia 634041 www micran com...

Reviews: