MODEL: EDM MM50 & MM80
MAGNETIC LINEAR SLIDING DOOR OPERATOR
Page 12
2.8 Wiring
2.8.1 Power Input & Mains Switch
1. Power Switch On/Off Plug In.
2. AC100V
3. AC100V
4. EARTH
2.8.2 Harness Wiring
Activation Input (SS)
Cable
Red
Activation Signal Input
Green
Common
Black
AC100V output (Japan use only)
White
AC100V output (Japan use only)
Threshold Safety Input (SB)
Cable
Red
Safety Signal Input
Green
Common
Black
AC100V output (Japan use only)
White
AC100V output (Japan use only)
Vi-Part & Function Input/Output - AUTO Type Only
Cable
Yellow
Closed End Signal Output
Blue
Common (Closed End Output)
Purple
Bi-Parting Signal Input
Orange
Bi-Parting Signal Output
Green
Ground
Notes:
- Model MM50 & MM80 is a NC (Normally Closed) circuit.
0 Voltage output of SS, SB, Vi-Part & Function Cables.
100V AC 1A output of Black and White cables to be
isolated (Japan use only).
SB =
Safety
SS =
Activation
Vi-Part & Function
(AUTO Type)