3. Operation
3.1 Teaching or Learning Operation
Learning Cycle-
With the Power ON/OFF Switch provided, power can be switched ON to begin
the Teaching Stoke process.
Teaching will begin once the power is turned ON. A full open and close cycle
stroke will be performed at SLOW speed.
CAUTION: When learning, allow the Door to Fully Open / Close. If sensors are
fitted, step back from the activation area. Do not obstruct the door when
teaching.
Each time the power is switched OFF (by switch or power cut), a teaching stroke must be carried out at the next
power ON.
3.1.1 Learning Operation - Door Starting Position:
(a) Closed
–
Activate to start the teaching process. The door will start to move SLOWLY in
the open direction. Once the door has reached its FULL open position, it will
return SLOWLY in the closing direction, until FULLY CLOSED.
Do not stand in the detection area when the door is teaching, as it will not
close.
(b) Not Closed
–
The door will start to automatically close to the fully closed end. Once reaching
FULLY closed position, teaching can be performed as above.
(c) Closed with E-Lock -
If the operator is fitted with E-Lock, the teaching will always being with the door in FULLY closed and LOCKED
position.
(d) Teaching Complete -
Once the door has opened fully and then returned to the fully closed position and stopped
– teaching is complete.
3.2 Normal Operation
After the teaching process is successfully completed, the operator will be ready to accept all customary activations.
With door in closed position, it can be activated to open. After pre-set open time, the door will close. It will re-open if
any activation signal or safety signal is turned on. If there is no such activation, the door will close fully.
With an E-Lock fitted, the door will lock after it is fully closed.
CAUTION: If the door does not stop at the closed end position and re-opens automatically. The operator is not
installed correctly. Please contact your MICOM Representative or email: