6.2 Applicable Door Size 
 

MM50 & MM80 

  

Rail Length (mm) 

Entrance Width (mm) 

Standard Size Option 

Single - Left / 

Right 

1666 / 1925 / 
2232 / 2512 /  

2710 

833 / 962.5 / 1116 / 1256 / 1355 

Cut to Size (Made to Order) 

Single 

1500 - 1800 

750 - 900 

1801 - 2200 

900 - 1100 

2201 - 2710 

1100 - 1350 

2711 - 3200 

1355 - 1600 

 

7. Electronic Lock (Option) 

NOTE: E-Lock is available with AUTO type only. Assist type 
does not support E-Lock. E-Lock offers LK1 FAILSAFE 
(UNLOCK without power) function only. 

 
If an E-lock is fitted, it is not possible to open the door by hand. The 
door will be unlocked upon an activation signal to the controller and 
open automatically. Once a full open and close cycle has been 
performed, the door will lock with E-lock once fully closed. 
 
If there is a problem with the E-Lock, the controller will show this 
when either in teaching mode or during normal operation.  
 
7.1 Teaching with E-Lock 
 
LED will flash RED with Buzzer. 

 

 

Lock output Signal 
(Option 

– With Counter) 

 
Wiring:  
Red 

– Lock output 

signal 
Black 

– Com 

 
Load Capacity:  0.3A / 
AC125V / 1A / DC24V 

 

E-Lock Harness 

E-Lock Body 

Summary of Contents for EDM MM50

Page 1: ...G DOOR OPERATOR Page 1 MAGNETIC LINEAR SLIDING DOOR OPERATOR INSTALLATION INSTRUCTIONS _________________________________ MODEL EDM MM50 MM80 Auto Assist Version Japanese Type ORIGINAL INSTRUCTIONS DATE 2011 MICOM Autodoor Osaka Japan No MM0004 ...

Page 2: ...eates steam heat or a humidifier Do not touch when a lightning storm occurs Should a burning smell be detected switch power off at fuse Contact your MICOM representative immediately Do not put hands flammable liquids gases or items affected by high temperatures onto operator during operation Do not spray pesticides or detergents onto operator directly CAUTION Avoidance of Injury and Malfunctions E...

Page 3: ...ng To be performed by authorised personnel only With power OFF Using neutral detergent wet and twist a soft cloth to wipe clean the operator If power is not switched off before cleaning there is risk of electrocution or personal injury due to door movement IMPORTANT NOTICE TO USER Do not hang any items on the rail or door as this will cause improper operation of sensors and function of door operat...

Page 4: ...ction Obstruction Protection E Lock LK1 Fail Safe Option Push Go Function Open Speed Adjuster Partial Open Adjuster Open Timer Ratchet Switch Flip Flop Function Hold Open Function Setting By Hand Free Stop Function Setting By Hand Obstruction Protection 1 1 Parts No Part Description 1 Control Box Assembly MM50 MM80 Assist Type 2 Magnetic Linear Motor MM50 MM80 3 Moving Magnet 4 Stopper 5 Hanger Ro...

Page 5: ... ON Activation Signal Safety Signal Input Green LED OFF LED RED ON Over Heating Protection Automatically Stop Open LED RED FLASHING SLOWLY Obstruction Stop LED RED FLASHING QUICKLY with Beep Problem with E Lock 5 Open Speed Adjuster 200 500mm s Default 400mm s 6 Model AUTO Type Close Speed Adjuster 200 500mm s Default 300mm s 6 Model ASSIST type Partial Open Adjuster 0 50 10 100 7 Open Timer Adjus...

Page 6: ...metal particles 2 2 Applicable Door Applicable Door Width 100mm 50mm Each Side of Magnet Length Applicable Door Magnet Length 800mm Door Width Min 700mm to Max 900mm Magnet Length 900mm Door Width Min 800mm to Max 1000mm Magnet Length 1100mm Door Width Min 1000mm to Max 1200mm Note Door position and alignment to magnet can be left side right side or central depending on requirement ...

Page 7: ...n If the pitch is too close the door will not move smoothly Fix with M8 Bolts supplied 2 3 1 Moving Magnet Fixing Plate Pitch Adjustment Loosen x2 M4 screws and adjust the position of the fixing plate to same distance as Hanger on door do not forget to re tighten Note Adjust Fixing Plate of Closing side only 185mm Hanger Pitch Fixing Plate Pitch ...

Page 8: ...Operator Using appropriate fixing attach operator to horizontal surface 2 4 Installation of Door Step1 Position door without fixing Step2 Hanging Door Use 1 st X3 Plastic Protection Plates Do not remove To protect Linear Motor and Magnet during installation Retain to future maintenance ...

Page 9: ...G DOOR OPERATOR Page 9 Step3 Hanging Door Use 2 nd Door mounted without tightening hangers Step4 Tightening hangers with M8 nut Once bolts are tightened door and hangers will be aligned Secure door leaf with M8 Nut X3 Plastic Protection Plates ...

Page 10: ...r and moving magnet before the hanger assemblies are tightened Note Please keep protection plates for future maintenance requirement With door hung on Hanger bracket but not tightened ensure plastic protection plates are in place Tighten M8 nut with flat washer Maintain exact Horizontal and Vertical alignment 2 6 Stopper Installation IMPORTANT Confirm linear motor and moving magnet are EXACTLY 2mm...

Page 11: ...s explained below Note If there is not enough overlap this will be cause of defective operation Full Closed X Full Open X Correction Position of Moving Magnet 30mm Min Magnet Overlap Distance White Mark Incorrect Position of Moving Magnet Correction Position of Moving Magnet 30mm Min Magnet Overlap Distance White Mark Incorrect Position of Moving Magnet 30mm 30mm Motor Motor Moving Magnet Moving M...

Page 12: ... Input SB Cable Red Safety Signal Input Green Common Black AC100V output Japan use only White AC100V output Japan use only Vi Part Function Input Output AUTO Type Only Cable Yellow Closed End Signal Output Blue Common Closed End Output Purple Bi Parting Signal Input Orange Bi Parting Signal Output Green Ground Notes Model MM50 MM80 is a NC Normally Closed circuit 0 Voltage output of SS SB Vi Part ...

Page 13: ...on area when the door is teaching as it will not close b Not Closed The door will start to automatically close to the fully closed end Once reaching FULLY closed position teaching can be performed as above c Closed with E Lock If the operator is fitted with E Lock the teaching will always being with the door in FULLY closed and LOCKED position d Teaching Complete Once the door has opened fully and...

Page 14: ...ial Open is adjustable by the Partial Open adjuster Adjustable range 0 50 to 10 100 Open Factory Setting at 100 Full Open Partial open is a fixed setting by control The use of a Partial Open Switch Selection is not applicable Partial Open setting is effective after activation through SS input When activation by hand Push Go Partial Open setting is ignored and door opens to 100 Full open e Ratchet ...

Page 15: ...PEN ADJUSTER 2 Partial Open is adjustable by the Partial Open adjuster Adjustable range 0 50 to 10 100 Open Factory Setting at 100 Full Open Note Partial open is a fixed setting by control The use of a Partial Open Switch Selection is not applicable 4 3 OPEN TIMER RATCHET ADJUSTER 3 Open time will begin when the door has reached its full open position Turning Right Longer L Adjustable range is 1 1...

Page 16: ...2 Factory Setting Connected Connected 30 40kg 30 40kg 3 Disconnected Connected 20 30kg 20 30kg Light 4 Disconnected Disconnected 20 25kg 20 25kg NOTE Above door size and weight should be used as a guide only Please check breaking force setting by sight For Example Door Open Close Force Level 2 Factory setting Plug no 1 Plug no 2 Connected If the braking is too weak door hits a little hard Set to l...

Page 17: ...tory Setting Connected Connected 30 40kg 30 40kg 3 Disconnected Connected 20 30kg 20 30kg Light 4 Disconnected Disconnected 20 25kg 20 25kg NOTE Above door size and weight should be used as a guide only Please check breaking force setting by sight For Example Door Open Close Force Level 2 Factory setting Plug no 1 Plug no 2 Connected If the braking is too weak door hits a little hard Set to level ...

Page 18: ... SS Does not open with wireless touch switch or button Wire from receiver of touch switch is disconnected There is an obstruction stopping signal Battery and direction are ok Channel of switch and received is same 6 Specification 6 1 Technical Model EDM MM 50 EDM MM 80 Application ASSIT Single AUTO Single or Vi Part ASSIT Single AUTO Single or Vi Part Door Weight max 20 50 Kg per Leaf 20 80kg per ...

Page 19: ...FETY SIGNAL INPUT RED ACTIVATION SB GREEN COM WHITE 100VDC Japan Only BLACK 100VDC Japan Only C VI PART FUNCTION SIGNAL INPUT OUTPUT BLUE COM CLOSE END OUTPUT YELLOW CLOSED END OUTPUT GREEN COM ORANGE VI PARTING OUTPUT PURPLE VI PARTING OUTPUT Note Model MM50 MM80 is a NC Normally Closed circuit 0 Voltage output of SS SB Vi Part Function Cables 100V AC 1A output of Black and White cables to be iso...

Page 20: ...MODEL EDM MM50 MM80 MAGNETIC LINEAR SLIDING DOOR OPERATOR Page 20 Basic Wiring Single Bi Part Activation Safety Vi Parting Synchronization Bi Part ...

Page 21: ...ndividual Operation by Switch Notes When door is synchronized using Vi Parting connection it is possible to include a switch to change operation for Single Door use SWITCH ON Synchronization SWITCH OFF Individual Interlock Notes Door 1 will not open if door 2 is open Door 2 will not open is door 1 is open ...

Page 22: ...d Output Signal Digital Counter Option Wiring Yellow Closed End Signal Blue Com Closed End Signal Load Capacity 0 3A AC125V 1A DC24V Security Wiring Option Access Control Notes Door will open and close when access is authorized from card reader keypad or other security system ...

Page 23: ...IDING DOOR OPERATOR Page 23 Security Wiring Option Timer Notes Door will open and close by activation only during pre set time Security Wiring Option Timer Access Notes Entering room is restricted with timer device Exit from room is allowed ...

Page 24: ... Lock offers LK1 FAILSAFE UNLOCK without power function only If an E lock is fitted it is not possible to open the door by hand The door will be unlocked upon an activation signal to the controller and open automatically Once a full open and close cycle has been performed the door will lock with E lock once fully closed If there is a problem with the E Lock the controller will show this when eithe...

Page 25: ...e applied in compliance with safety standards The occupier is responsible for the undertaking of the following test procedure which should be carried out at least weakly unless a different schedule of tests is identified in the risk assessment priory to installation 1 There should be no notice boards literature racks merchandise displays or other distractions or obstructions in the vicinity of the...

Page 26: ...Prismatic and Folding Door Site Serial No Door Type Opening Width Time Open Time sec Closing Time sec Hold Open Time sec Closing Energies Commissioning Only At Low Speed J At Max Speed J Static Entrapment Force N Activation Distances Straight Approach m Side Approach m Safety Device s Hold Open Beams Number Fitted Height s above Floor Level m Presence Sensors Field Width m Field Depth m Hold Open ...

Reviews: