- 13 -
When memory is full, it will take about two minutes to upload all history data into PC and it takes
another two minutes to process all history data for graphic display.
Further detailed PC software user manual can be found from the help menu.
Specifications
Outdoor data
Transmission distance in open field : 100m(300 feet)
Frequency : 433MHz
Temperature range : -40˚C--65˚C (-40
℉
to +149
℉
)
Accuracy : + / - 1 °C
Resolution : 0.1˚C
Measuring range rel. humidity : 10%
~
99%
Accuracy : +/- 5%
Rain volume display : 0 – 9999mm (show --- if outside range)
Accuracy : + / - 10%
Resolution : 0.3mm (if rain volume < 1000mm)
1mm (if rain volume > 1000mm)
Wind speed : 0-160km/h (0~100mph) (show --- if outside range)
Accuracy: +/- 1m/s (wind speed< 10m/s)
+/-10% (wind speed > 10m/s)
Measuring interval thermo-hygro sensor: 48 sec
Water proof level : IPX3
Indoor data
Measuring interval pressure / temperature : 48 sec