SB44SS Outdoor Woodburning Fireplace
8
87D0059
CLearaNCeS
OuTSIde INSTaLLaTION
8’ Min.
FP2245
typ outdoor install
Sample Outdoor Installation -
for reference Only
Telscoping Chimney
Cap
Flat Flashing
Chimney Section
Exterior Grade
Finish Materials
Removed for Clairty
Metal Safety Strip
(Required when place on a
combustible floor)
Hearth Extension
(Required when placed on a
combustible floor)
FP45
” Min.
Clearance to
Combustibles
(Both Sides)
Use Only
Noncombustible
Materials Below
Top of Spacers
Figure 4
12”
Max.
M1002
Mantel install
8/08
Mantel Installation
Combustible Framing
Members to Top of
Spacers
Combustible Mantel
Top Edge of Fireplace
18” Min. From Fireplace Opening to
Bottom of Combustible Mantel
(Manufacturuer Recommendation)
Top Edge of Fireplace
Opening
M100
64
56QE
” Min.
53
6
”
19
6
”
Min.
92
6
” Min.
19
6
”
Min.
**16"
Min.
1
56O
”
Air Space
Clearance
27
(6
”
Min.
FP2237
SB65400 framing
23
56O
" Min.
*28” Min.
*Applies when Glass Doors are not installed
**Applies when Glass Doors are installed
Sidewall Installation
FP37
1/2” (13 mm)
FP1642
concrete install
9/06
NOTe:
When installation is on a
hard, flat surface (such as con-
crete), the surface must be sloped
1/4” per foot away from any sruc-
ture.
Blocking
Metal Safety
Strips
Hard, Flat Surface
(i.e. Concrete)
FP164