SB44SS Outdoor Woodburning Fireplace
87D0059
11
INSTaLLaTION preparaTION
18’ Min.
FP1881
single story install
8/08
Chimney Cap
Single Story Installation with attic Space
Storm Collar
Flashing
Flue Outlet Height
3’ Min. or ’ Above
any Point within 10’
See Table
1 for Roof
Opening Size
Attic Space
Firestop Spacer
(” Air space
Clearance to
Combustibles)
Chimney
Sections
17”
Square
Opening
in Joist
FP1881
Figure 9
FP1882
chimney location
8/08
Figure 10
Preferred Location
Poor Location
FP188
3 ft. Min.
FP1883
multistory install
8/08
Multiple Story Installation
Chimney Cap
Storm Collar
(Included with cap)
Flashing
See Table 1 for
Roof Opening
Size
Attic Space
Firestop
Spacer (”
Air Space
Clearance to
Combustibles)
” Clearance to
Combustibles (Min.)
17” Square Open-
ing in Joist
Max.
Installation
height -
86 ft.
Third Floor
Area
Second
Floor Area
First Floor
Area
Flue Outlet Height
17” Square
Opening in
Joist
17” Square
Opening in Joist
Firestop
Spacer
Firestop
Spacer
FP1883
INSuLaTINg FIrepLaCe eNCLOSure FOr
COLd CLIMaTeS
If you live in a cold climate, it is not required but highly
recommended
that you insulate the fireplace enclosure to
eliminate cold air penetration as much as possible.
Insulate base of fireplace with a noncombustible insulation
rated for a minimum of 300° F. Insulating is very important
for outside wall installations over a concrete slab. If fireplace
is installed on a platform, insulation should be placed on top
of the platform before fireplace is set.
Figure 8
When a fireplace is installed in a chase or on an outside wall,
enclosure should be treated like any outside wall in a home.
Insulation should be installed on the inside wall as well as the
outside wall(s). In a chase, it is also a good idea to install a
firestop at the first ceiling level above the fireplace and en-
close the chase with sheeting material. Insulation may then be
installed above sheeting material to assure the space around
the fireplace is totally protected.
Figure 8
CauTION: WheN INSTaLLINg a FIrepLaCe IN aN IN-
SuLaTed eNCLOSure, Be Sure aLL requIred aIr
SpaCeS are MaINTaINed.
Figures 9 & 11
Figure 11