9.4.2.
Manually
At Manual-
mode with button “Start” one index and working cycle will be processed
.
The following buttons are displayed:
Button
Functional description
Is used for the sequential start of a new print job/run. It
activates each selected print station/flash cure unit in
sequence when commencing a production run. After the
first complete printing cycle with all enabled print
stations/flash cure units, the startup mode will be turned
off automatically.
Is used to switch off the print stations one by one when
print job is finished.
Warming up the pallets to working temperature. For this
only active drying stations are used. Warming up is
necessary to get the same print results from the
beginning.
Moves the tables to the clean/half index position.
Start a print cycle including index. An optional foot switch
provides the same function, only the first start command
must always be given at the control panel.