5.4.1.
Electrical Connections
The electrical connections must be designed as follows:
Description
Requirement/Value
Supply voltage
3 ph. ~ 210 / 400V AC
Supply frequency
50/60Hz ±5%
Connected load
0.4 kVA x
“
number of print heads
”
+ 3,1 kVA
5.4.2.
Compressed Air
Description
Value
Air pressure
(minimum)
8 bar / 116 PSI
Air quality
filtered, dry air supply only (class 1:4:1 according ISO8573-
1:2010)
Max. air consumption
(l/min)
30 l/min x
„
number of print heads
“
+
5 l/min x
„
number of tables
“
Risk of electric shock!
Please observe the general safety regulations for electrical
connections when connecting the mains supply to the iQ-Oval CDS.
Avoid any contact with live components.
All flash cure units must be supplied through a
separate/independent connection. Please observe the precise
technical data from the flash cure unit specification sheet.