9.1.4.
Stopping the Machine in the event of Malfunction
If the main control system detects any electrical or mechanical malfunction, all drives
will be disabled/de-activated automatically for the safety and protection of the
operating staff. A respective error message will be shown on the tablet or terminal.
9.1.5.
Long-term Shutdown
This refers to a scheduled long-term shutdown of the iQ-Oval CDS. The following steps
must be carried out:
▪
Remove all the printing screens along with the pallets.
▪
Clean all print stations.
▪
Switch off tablet. Press “Main switch tablet” for longer than
one second to start
special menu. Press “Power off” when displayed.
▪
Switch off control power supply with “Control ON/OFF”.
▪
Disconnect the power supply with main power switch.
▪
Switch off the compressed air supply.
▪
Carry out a thorough cleaning of the machine.
9.1.6.
Permanent Shutdown of the Machine
If the iQ-Oval CDS is to be shut down permanently or decommissioned (e.g. disposed
of/scrapped), upon disassembly all individual parts must be disposed of according to
their class of substance, in accordance with all respective regulations in effect at that
time in the machine’s particular location/country, through a licensed waste
-disposal
company.
9.2.
Configuration of the Control
The iQ-Oval CDS is equipped with the MHM Hybrid-Control system. This allows
controlling the machine with the terminal unit when tablet “m
-
touch pro” is defective.
At the print stations keypads with separate displays are located. Every table is
equipped with an individual drive unit.
9.3.
Hybrid-Control
Hybrid-
Control enables machine controlling either with the tablet “m
-
touch pro” or
with the terminal. The communication between the different components is
established by connected cables or Bluetooth. To change to operation by terminal
disconnect the tablet and close the application with the button “Close Application” in
“BasicSetup”.
Alternatively, the tablet can be switched off completely or be
transported outside of the Bluetooth transmission range.