MHG Heating procon gwb smartline Installer And User Manual Download Page 6

6

  ProCon  Smartline

10 - TECHNICAL DATA

15 H

25,00
21.500
24,3
20.898
26,30
22.575
7,00
6.020
6,8
5.863
7,4
6.405
97,2 - 97,4
102,2
97,9
105,0  -  106,4
108,1
132
II2H3P
230 - 50
X5D (C type) -  X4D (B type)
2,10 - 0,70

3 - 90
0,25 - 0,45
20/45-40/80
300
1000

20
37

3/4”
3/4”
3/4”

780
400
358
40

100

39,689
42,697
14,37  -  3,17

60 - 100
7,85
0,85/0,5
105

80 - 125
17
0,85/0,5
130

80
40 + 40
0,8/0,5

80
48
0,8/0,5
5  class

93
8,5
25
72
15
9,0
20
58

25  HS

15,00
12.900
14,5
12.500
15,70
13.532
3,50
3.010
3,4
2.926
3,8
3.269
96,9 - 97,2
101,5
97,4
104,9  -  108
108,4
96
II2H3P
230 - 50
X5D (C type) -  X4D (B type)
2,60 - 0,50

3 - 90
0,25 - 0,45
20/45-40/80
240
1000

20
37

3/4”
3/4”
3/4”

780
400
358
38

80

18,742
20,246
6,79 - 1,59

60 - 100
7,85
0,85/0,5
105

80 - 125
17
0,85/0,5
130

80
50 + 50
0,8/0,5

80
80
0,8/0,5
5  class

90
9,0
35
64
10
9,0
25
58

15  HS

CH

Nominal  thermal  flow  rate

Nominal  thermal  power  (80°/60°)

Nominal  thermal  power  (50°/30°)

Reduced  thermal  flow  rate

Reduced  thermal  power  (80°/60°)

Reduced  thermal  power  (50°/30°)

Working  efficiency  Pn  max  -  Pn  min  (80°/60°)
Working  efficiency  30%  (47°  return)
Combustion  efficiency
Working  efficiency  Pn  max  -  Pn  min  (50°/30°)
Working  efficiency  30%  (30°  return)
Electric  power
Category
Supply  voltage
Protection  level
Chimney  and  skirt  losses  with  burner  on
CH  operation
Maximum  pressure  -  temperature
Minimum  pressure  for  standard  operating
Selection  field  of  CH  water  temperature
Pump:  maximum  head  available  for  system

capacity

Gas  pressure
Natural  gas  pressure  (G20)
LPG  pressure  (G31)
Hydraulic  connections
CH  input-output
Water  tank  delivery-return
Gas  input
Boiler dimensions and weight
Height
Width
Depth
Weight
Fan  performance
Residual  head  separated  pipes  0,5  m  +  Ø  80  mm
Flow rates (G20)
Air  capacity
Fumes  capacity
Mass  flow  (max-min)
Fume exhaustion and air suction concentric pipe
Diameter
Max  lenght
Loss  for  a  90°/45°  bend
Hole  in  wall  (diameter)
Fume exhaustion and air suction concentric pipe
Diameter
Max  lenght
Loss  for  a  90°/45°  bend
Hole  in  wall  (diameter)
Fume exhaustion and air suction separated pipe
Diameter
Max  lenght
Loss  for  a  90°/45°  bend
Forced  open  installation  (B23P/B53P)
Diameter
Max  lenght
Loss  for  a  90°/45°  bend
NOx
Emission values at maximum and minimum of gas G20 ***
Maximum

CO s.a. lower than
CO

2

NOx s.a. lower than

t fumes

Minimum

CO s.a. lower than
CO

2

NOx s.a. lower than

t fumes

kW

kcal/h

kW

kcal/h

kW

kcal/h

kW

kcal/h

kW

kcal/h

kW

kcal/h

%
%
%
%
%
W

V - Hz

IP
%

bar-°C

bar

°C

mbar

l/h

mbar
mbar

Ø
Ø
Ø

mm
mm
mm

kg

Pa

Nm

3

/h

Nm

3

/h

gr/s

mm

m
m

mm

mm

m
m

mm

m
m

mm

m
m

p.p.m.

%

p.p.m.

°C

p.p.m.

%

p.p.m.

°C

** Estimated with one 90° bend, 24 one-metre extensions and a horizontal 1-metre manifold.
*** Tested with ø 60-100 concentric - lenght 0,85m - water temperature 80-60°C.

15,00
12.900
14,5
12.500
15,70
13.532
3,50
3.010
3,4
2.926
3,8
3.269
96,9 - 97,2
101,5
97,4
104,9 - 108,6
108,4
96
II2H3P
230 - 50
X5D (C type) -  X4D (B type)
2,60 - 0,50

3 - 90
0,25 - 0,45
20/45-40/80
240
1000

20
37

3/4”
3/4”
3/4”

780
400
358
38

80

18,742
20,246
6,79 - 1,59

60 - 100
7,85
0,85/0,5
105

80 - 125
17
0,85/0,5
130

80
50 + 50
0,8/0,5

80
80
0,8/0,5
5  class

90
9,0
35
64
10
9,0
25
58

Summary of Contents for procon gwb smartline

Page 1: ...er and user manual ES Manual de instalaci n y uso PL Instrukcja obs ugi instalacji i konserwacji RO Manual de instalare si utilizare DK Installations og brugervejledning FR Manuel d installation et d...

Page 2: ...o al usuario como al instalador PL RO Acest manual contine date si informatii atat pentru utilizator cat si pentru instalator Si anume Capitolele intitulate Instalarea cazanului Conectare la reteaua d...

Page 3: ...display and disconnect the electricity supply by turning off the two position system switch before cleaning It is forbidden to modify the safety or adjustment devices without the manufacturer s permis...

Page 4: ...e the supplied power cable to connect the boiler to the mains power supply Connect the ambient thermostat and or external programmable timer clock as shown in the electrical diagram on page 75 When re...

Page 5: ...towards the boiler Non insulated fumes outlet ducts are potential sources of danger The boiler automatically adapts ventilation according to the type of installation and the length of the duct Do not...

Page 6: ...ity Gas pressure Natural gas pressure G20 LPG pressure G31 Hydraulic connections CH input output Water tank delivery return Gas input Boiler dimensions and weight Height Width Depth Weight Fan perform...

Page 7: ...me exhaustion and air suction concentric pipe Diameter Max lenght Loss for a 90 45 bend Hole in wall diameter Fume exhaustion and air suction concentric pipe Diameter Max lenght Loss for a 90 45 bend...

Page 8: ...an ProCon Smartline 30 S Number of main burner nozzles Gas diaphragm CH maximum gas capacity DHW maximum gas capacity CH minimum gas capacity DHW minimum gas capacity Fan speed at slow start Maximum s...

Page 9: ...he domestic hot water in the water tank turn the temperature selector clockwise to increase and anticlockwise to decrease The adjustment range lies between 35 and 60 C When choosing the temperature bo...

Page 10: ...er circuit should only be considered if a water tank is installed case C accessory available on request 12 1 A green indicator LED boiler status 12 6 12 7 12 8 B red indicator LED fault 12 9 12 10 12...

Page 11: ...ating curve to that value E g if the value obtained by the calculation is 1 3 it lies between curve 1 and curve 1 5 In this case select the nearest curve i e 1 5 Select KT by turning the trimmer locat...

Page 12: ...the board generates an alarm If a fault develops during the combustion analysis phase perform the release procedure as follows Turn the function selector 6 to then to and then move it to the required...

Page 13: ...mes To exit and return to the current operating mode press and release the P button OPERATING MODES Each channel C1 C2 has 3 different modes of operation Automatic using the stored ON OFF settings ON...

Page 14: ...ik 22 G wny wymiennik ciep a 23 Mieszalnik 24 Wentylator 25 Dolny zaw r odpowietrzaj cy 26 Pompa cyrkulacji 27 Prze cznik przep ywowy S 28 Wymiennik ciep a gor cej domowej wody S 29 Silnik zaworu tr j...

Page 15: ...dpowietrzaj cy U Cyrkulator V Wymiennikciep agor cejdomowejwody W Zaw r tr jdro ny X Regulator przep ywu Y Prze cznik przep ywowy RO Circuit hidraulic S RO Circuit hidraulic S RO Circuit hidraulic S R...

Page 16: ...powietrzaj cy Q Separator wody powietrza R Zaw r r cznego odpowietrzania S Dolny zaw r odpowietrzaj cy T Cyrkulator U Silnik zaworu tr jdro nego V Zbiornik wody dost pny na danie RO Circuit hidraulic...

Page 17: ...71 ProCon Smartline ProCon Smartline S...

Page 18: ...72 ProCon Smartline ProCon Smartline HS...

Page 19: ...tank thermostat M2 M4 water tank probe terminal strip HS External probe remote control M4 External probe remote control V1 V2 Gas valve operator P Pump W D S Water pressure switch P1 Domestic hot wat...

Page 20: ...dere I E 2 Electrod de relevare flacara F Siguranta 3 15A F rapida F1 F2 Siguranta 3 15A T intarziata DFS Fluxostat sanitar S JP5 Jumper preselectare config centrala poz 5 pentru S JP2 Jumper preselec...

Page 21: ...ea termostatului de ambient si sau RO Conectarea termostatului de ambient si sau RO Conectarea termostatului de ambient si sau RO Conectarea termostatului de ambient si sau a programatorului or a prog...

Page 22: ...i wymagany jest wy szy s up wody dost pny na danie jest zestaw cyrkulatora wysokiego s upa wody wykresy 3 4 prima velocita pierwsza pr dko seconda velocita druga pr dko terza velocita trzecia pr dko R...

Page 23: ...ons in mm ES Medidas en mm PL Wymiary w mm RO Dimensiuni in mm DK Dimensioner i mm FR Dimension en mm EN H Water gas ES H Agua gas PL H Woda gaz RO H Apa gaz DK H Vand gas FR H Gaz eau A B 30 S 452 5...

Page 24: ...ax 50 cm ES A Salida trasera B M x 50 cm PL A Tylny wylot B Maks 50 cm RO RO RO RO RO A Supapa posterioara B Max 50 cm DK A Bagerste udtag B Max 50 cm FR A Sortie arri re B Maxi 50 cm C13 C13 C53 C53...

Page 25: ...evacuare fum aspirare aer C Tuburi separate pentru evacuare fum aspirare aer D Adaptor 60 80 DK A R ggasaftr k til indtag i omgivelser B Balanceret aftr k til r ggasudtag luftindtag C Splitkanal til r...

Page 26: ...O RO RO RO RO A Curbe de termoreglare B Corectarea curbei de temperatura C Paralele diminuare grad confort D Temperatura de pe tur C E Temperatura externa C F T80 Set point temperatura maxima de incal...

Page 27: ......

Reviews: