6
ProCon Smartline
10 - TECHNICAL DATA
15 H
25,00
21.500
24,3
20.898
26,30
22.575
7,00
6.020
6,8
5.863
7,4
6.405
97,2 - 97,4
102,2
97,9
105,0 - 106,4
108,1
132
II2H3P
230 - 50
X5D (C type) - X4D (B type)
2,10 - 0,70
3 - 90
0,25 - 0,45
20/45-40/80
300
1000
20
37
3/4”
3/4”
3/4”
780
400
358
40
100
39,689
42,697
14,37 - 3,17
60 - 100
7,85
0,85/0,5
105
80 - 125
17
0,85/0,5
130
80
40 + 40
0,8/0,5
80
48
0,8/0,5
5 class
93
8,5
25
72
15
9,0
20
58
25 HS
15,00
12.900
14,5
12.500
15,70
13.532
3,50
3.010
3,4
2.926
3,8
3.269
96,9 - 97,2
101,5
97,4
104,9 - 108
108,4
96
II2H3P
230 - 50
X5D (C type) - X4D (B type)
2,60 - 0,50
3 - 90
0,25 - 0,45
20/45-40/80
240
1000
20
37
3/4”
3/4”
3/4”
780
400
358
38
80
18,742
20,246
6,79 - 1,59
60 - 100
7,85
0,85/0,5
105
80 - 125
17
0,85/0,5
130
80
50 + 50
0,8/0,5
80
80
0,8/0,5
5 class
90
9,0
35
64
10
9,0
25
58
15 HS
CH
Nominal thermal flow rate
Nominal thermal power (80°/60°)
Nominal thermal power (50°/30°)
Reduced thermal flow rate
Reduced thermal power (80°/60°)
Reduced thermal power (50°/30°)
Working efficiency Pn max - Pn min (80°/60°)
Working efficiency 30% (47° return)
Combustion efficiency
Working efficiency Pn max - Pn min (50°/30°)
Working efficiency 30% (30° return)
Electric power
Category
Supply voltage
Protection level
Chimney and skirt losses with burner on
CH operation
Maximum pressure - temperature
Minimum pressure for standard operating
Selection field of CH water temperature
Pump: maximum head available for system
capacity
Gas pressure
Natural gas pressure (G20)
LPG pressure (G31)
Hydraulic connections
CH input-output
Water tank delivery-return
Gas input
Boiler dimensions and weight
Height
Width
Depth
Weight
Fan performance
Residual head separated pipes 0,5 m + Ø 80 mm
Flow rates (G20)
Air capacity
Fumes capacity
Mass flow (max-min)
Fume exhaustion and air suction concentric pipe
Diameter
Max lenght
Loss for a 90°/45° bend
Hole in wall (diameter)
Fume exhaustion and air suction concentric pipe
Diameter
Max lenght
Loss for a 90°/45° bend
Hole in wall (diameter)
Fume exhaustion and air suction separated pipe
Diameter
Max lenght
Loss for a 90°/45° bend
Forced open installation (B23P/B53P)
Diameter
Max lenght
Loss for a 90°/45° bend
NOx
Emission values at maximum and minimum of gas G20 ***
Maximum
CO s.a. lower than
CO
2
NOx s.a. lower than
∆
t fumes
Minimum
CO s.a. lower than
CO
2
NOx s.a. lower than
∆
t fumes
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
%
%
%
%
%
W
V - Hz
IP
%
bar-°C
bar
°C
mbar
l/h
mbar
mbar
Ø
Ø
Ø
mm
mm
mm
kg
Pa
Nm
3
/h
Nm
3
/h
gr/s
mm
m
m
mm
mm
m
m
mm
m
m
mm
m
m
p.p.m.
%
p.p.m.
°C
p.p.m.
%
p.p.m.
°C
** Estimated with one 90° bend, 24 one-metre extensions and a horizontal 1-metre manifold.
*** Tested with ø 60-100 concentric - lenght 0,85m - water temperature 80-60°C.
15,00
12.900
14,5
12.500
15,70
13.532
3,50
3.010
3,4
2.926
3,8
3.269
96,9 - 97,2
101,5
97,4
104,9 - 108,6
108,4
96
II2H3P
230 - 50
X5D (C type) - X4D (B type)
2,60 - 0,50
3 - 90
0,25 - 0,45
20/45-40/80
240
1000
20
37
3/4”
3/4”
3/4”
780
400
358
38
80
18,742
20,246
6,79 - 1,59
60 - 100
7,85
0,85/0,5
105
80 - 125
17
0,85/0,5
130
80
50 + 50
0,8/0,5
80
80
0,8/0,5
5 class
90
9,0
35
64
10
9,0
25
58
Summary of Contents for procon gwb smartline
Page 17: ...71 ProCon Smartline ProCon Smartline S...
Page 18: ...72 ProCon Smartline ProCon Smartline HS...
Page 27: ......