XTreme-EMS Operating Manual
Page 47
4.3.10 Volts Setup
VOLTS DISPLAY MAX:
Select the maximum value that you want the volts bargraph in the EMS display to show. This can give you increased
display resolution.
VOLTS DISPLAY MIN:
Select the minimum value that you want the volts bargraph in the EMS display to show. This can give you increased
display resolution.
HIGH ALARM:
This enables or disables the volts high alarm.
HIGH ALARM:
Enter the voltage threshold for when the high alarm must be activated. Any voltage above this value will activate the
alarm.
HIGH CAUTION:
Enter the voltage for the high caution. This is the lower value of the upper yellow band.
LOW CAUTION:
Enter the voltage for the low caution. This is the upper value of the lower yellow band.
LOW ALARM:
This enables or disables the volts low alarm.
LOW ALARM:
Enter the voltage threshold for when the low alarm must be activated. Any voltage below this value will activate the alarm.
LABEL:
Enter a label so you can identify it easily.
VOLTS CALIBRATION FACTOR:
Measure the battery voltage with a multimeter and then adjust this value to match that of the multimeters volts reading.