4.1.1.2  Initiating the shutdown procedure when the battery level is lower than: (Low Battery

Level)

When the SNMP agent detects that the remaining backup time percentage is less than the configured
level, the shutdown sequence is started.
By default, this value is set in the UPS.

Note:

Certain types of UPS only accept pre-defined minimum battery level values (e.g. : 20% or 40% for
COMET and PULSAR EXtreme). Check the UPS documentation.

4.1.1.3  Shutdown when backup time is less than

When the SNMP agent detects that the percentage of backup time remaining is less than the value
set, the shutdown sequence is started.

4.1.1.4 Shutdown 

duration

Duration required for the systems protected by UM-Client to shut down (in seconds).

4.1.2  Individual outlet control

Some UPS models are equipped with outlets or group of outlets (typically 2), that can be controlled  or
programmed individually (while still remaining dependent on the main UPS control). MGE name for
this feature is PowerShare.
Shutdown of the UPS systematically causes shutdown of the controlable outlets.

Depending on the UPS range, the following notation is used to mark these outlets:

 

Main outlet: 

Main   or

1

 

Programmable outlet 1

1

or

2

 

Programmable outlet 2

2

or

3

4.1.3  Connecting a server protected by UM-Client to a controlled outlet

After connecting the server electrically to one of the controlled outlets, UM-Client must be informed of
the outlet number to which it is connected.
Start UM-Editor (installed with Solution-Pac / WAN), select the “

Switchable plug

”  box and specify the

outlet number (1=main, 2 or 3) in the “

Receptacle Number

” field.

Summary of Contents for minislot 66244

Page 1: ...m Network Management Cards User Manual T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R Network Management Cards User Manual 34003676EN AA Pag SNMP Web Minislot card 66244 SNMP Web Transverse card 66074 ...

Page 2: ...k parameters 7 2 2 3 Rebooting the card 7 2 2 4 Restoring factory configuration 7 2 2 5 Lost password restoring the default password 7 2 2 5 HYPERLINK Erreur Signet non défini 2 2 6 Checking that the card works 7 3 SUPERVISION ADMINISTRATION VIA A WEB BROWSER 8 3 1 1 Optimising the performance of your browser 8 3 2 UPS 8 3 2 1 UPS properties page 8 3 2 2 On line help 11 3 2 3 UPS weekly schedule 1...

Page 3: ...GURATION IN LOCAL MODE 33 5 1 1 Choice 1 SNMP agent configuration menu 33 5 1 2 Choice 2 UPS parameters 35 5 1 3 Choice 3 Access control 35 5 1 4 Choice 4 NMS station subscription 36 5 1 5 Choice 5 Restore default configuration 36 5 1 6 Choice 6 Reset the card 36 5 2 CONFIGURATION VIA TELNET 36 6 MAINTENANCE 37 6 1 SOFTWARE UPGRADE 37 6 1 1 Card software upgrade using Mupgrade Windows 37 6 1 2 Car...

Page 4: ...Solution Pac WAN suite include The SNMP agent SNMP Web Card or UM Agent software supervises the UPS informs the UM Client of events occurring on the UPS by SNMP traps and manages UPS shutdowns and restarts UM Client protects the workstation on which it is installed and informs administrators and users of major events by network notification e mail SMS or fax with the Jericho alarm module under Win...

Page 5: ... MGE provides 2 different form factors for its SNMP Web cards SNMP Web Minislot card for UPS systems like the Evolution EXtreme C Pulsar EX Pulsar Comet DX series SNMP Web Transverse card for UPS systems like the Galaxy 3000 Galaxy PW Pulsar and Comet EXtreme series Other MGE UPS systems 3 phase Comet Galaxy EPS 6000 can be remotely managed using the Multislot card expander SNMP Web cards are SNMP...

Page 6: ...ected Up to 15 browsers connected at the same time Adjustment of date and time via NTP server Protection by encrypted password Saving of logs in the non volatile memory Automatic language detection according to OS configuration Languages available English French On line help available for each page Card firmware updated via the network 1 3 3 Network Fast ETHERNET 10 100 Mbits compatibility with au...

Page 7: ...rd or available for download on the www mgeups com web site in the Download area embedded Software section 2 1 5 Adjusting the network parameters Check the installation manual supplied with the card or available for download on the www mgeups com web site in the Download area embedded Software section 2 1 6 Rebooting the card Check the installation manual supplied with the card or available for do...

Page 8: ...nce of your browser To view status changes on the UPS in real time the browser must be configured so that it automatically refreshes all the objects on the current page Example on IE5 5 Tools menu Web options Parameters tick the Automatic box and validate Menu character size can be configured For an optimal and full view of the menu configure the browser with the Smaller option Example on IE5 5 Di...

Page 9: ...PS and the SNMP Web card in particular the model name and software version 3 2 1 2 UPS status zone essential information The various icons showing the status of the UPS are Utility power present Battery operation Loss of communication with the UPS Battery fault Communication indicates the status of the communication between the card and the UPS Power source indicates whether the power comes from t...

Page 10: ...osed whenever you wish As soon as a new event occurs on the UPS it is re opened automatically as long as your browser remains open To stop subscription click on the Unsubscribe button A warning message indicates the end of this subscription The button text becomes Subscribe again Note 1 If the browser is closed alarm notification is stopped but the subscription request remains in memory When the P...

Page 11: ...ards User Manual 34003676EN AA Page 11 42 3 2 2 On line help On line contextual help is available at the top of each page by clicking on the Help link which is always located in the top right corner The help browser menu is identical to that of the card pages The Help page always opens a new window ...

Page 12: ...tor to optimise power consumption or program a reboot of the protected equipment at a set time In a shutdown sequence the UM Clients connected to the card are informed and ensure that each machine is shut down correctly before the UPS output is switched off Up to 7 UPS shutdown sequences can be programmed in one week with a minimum shutdown period of 30 minutes Security the administrator clicks on...

Page 13: ...twork Management Cards User Manual 34003676EN AA Page 13 42 3 2 4 Viewing the alarms Click on the Alarm table section in the menu to view the list of current alarms The table of managed alarms is included in the appendix Note The alarm number is not related to the SNMP trap number ...

Page 14: ...ur UPS average of the 3 phases for UPSs with a 3 phase output Output load Value of the percentage of load at UPS output Value of the most loaded phase for 3 phase UPSs Battery capacity Percentage of charge available in the battery Remaining time Estimation of the remaining backup time The save frequency of these values is defined in the System page 60 seconds by default Approximately 500 time stam...

Page 15: ...www mgeups com T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R Network Management Cards User Manual 34003676EN AA Page 15 42 ...

Page 16: ... in the Event log section of the menu Save Log button enables all values saved to be opened or saved in CSV format compatible with Excel type spreadsheets Clear Log button enables deletion of all records The administrator must enter his her login password to validate this action Select the time range to view See the table of events generated in the Appendices ...

Page 17: ...lick in the System log section in the menu Save button enables all values saved to be opened or saved in CSV format compatible with Excel type spreadsheets Clear button enables deletion of all records The administrator must enter his her login password to validate this action Select the time range to view See the table of events generated in the Appendices ...

Page 18: ...ing the login and password these identifiers remain active as long as the browser is open so you only have to enter them once If the browser is closed they will have to be re entered Tick the Save this password in your password list box if you want to avoid systematic re entry An error in either field results in systematic rejection of the requested action save page access card reboot etc After th...

Page 19: ...le remote connection with a terminal BootP DHCP Authorises configuration of network parameters with your BootP DHCP server as startup mode choose enable Card operation mode with the server After all reboots if this option is enabled the card attempts to recover network parameters from the server for 10 sec If there is no response from the server the card boots with the last parameters saved during...

Page 20: ...isation of the refresh rate of the home page Its value by default is 10 sec Default language Enables initialisation of the browser language for card connection Auto Automatically displays the Web page texts in the same language as your browser If the SNMP web card is not able to display the recognised language the pages will be displayed in English English Displays the Web page texts in English re...

Page 21: ... managed by the card Note It is not necessary to add the UM Clients protecting your servers in this list as UM Clients are automatically added deleted Select an entry in the list to modify the values in the edit zone at the bottom of the page Device no field Use the 0 value for all manual entries NMS type field Select the value corresponding to the type of NMS used Possible choices UM Client DEC N...

Page 22: ...nformational 5 6 7 For more details read the MIB description document 34003627zjaa pdf available in the Embedded zone of the Web site Add entry button adds the record being edited to the list Delete entry button deletes the selected record Modify entry button enables modification of the selected record Save button Validates the edits made This operation is made secure by Login and Password entry 3...

Page 23: ...to 31 characters This field is only validated after clicking on Save Default value public Current Community Read Write is Enables read and write SNMP access control GET and SET Default value public Change Community Read Write Text field limited to 31 characters This field is only validated after clicking on Save Default value public Change Trap Port Number Numeric field limited to 65534 Enables fo...

Page 24: ...erver communicates GMT time The time zone of your geographic area must then be selected from the list Connection is made with the server and the date and time are set after clicking on the Save button Time is constantly updated Set manually Enables initialisation of the date and time of the card with the values entered in the Date and Time fields The adjustment is made after clicking on the Save b...

Page 25: ...re selected the first criterion encountered will launch the shutdown procedure At the end of the shutdown procedure when all servers have been shut down the UPS may shut down to avoid unnecessary discharge of its batteries depending on its configuration 4 1 1 1 Backup time before initiating the shutdown procedure Shutdown timer When the UPS switches to battery the SNMP agent starts the Shutdown Ti...

Page 26: ...own duration Duration required for the systems protected by UM Client to shut down in seconds 4 1 2 Individual outlet control Some UPS models are equipped with outlets or group of outlets typically 2 that can be controlled or programmed individually while still remaining dependent on the main UPS control MGE name for this feature is PowerShare Shutdown of the UPS systematically causes shutdown of ...

Page 27: ...s after a set battery back up time ShutOff Delay programmable in UM Console UM Vision 2 Shutdown of outlets at a given battery discharge level ShutOff Level programmable in UM Vision It is possible to specify values for both criteria The first criterion reached will initiate server shutdown 4 1 3 2 Sequential startup It is possible to delay outlet power on to reduce inrush currents on startup or t...

Page 28: ...e a client subscribes unsubscribes Shutdown Duration 1 2 Maximum value of shutdown times of the UM Client subscribed to the card and dependent on outlet 1 2 This value is updated each time a UM Client dependent on outlet 1 2 subscribes unsubscribes Note During battery operation these values are not updated 4 2 1 1 Main UPS outlet 1 Shuts down after the ShutDown Timer Shutdown Duration after having...

Page 29: ...age shutdown initiated by the Low battery power message When the Low battery power message is displayed the UPS is shut down after taking into account the shutdown timer of the servers Low battery power The message appears if either of the two following criteria is checked Low Battery Level Minimum remaining backup time Low Battery Delay 4 2 2 1 Main UPS outlet Utility Trap 17 Trap 11 Trap 29 Low ...

Page 30: ...n Timer but utility restoration before the end of the Shutdown Duration If utility power is restored before the end of the Shutdown Duration the UPS is shut down after the Shutdown Duration for a period equal to the forced reboot time delay 4 2 3 1 Main UPS outlet Utility Trap 17 Trap 11 Trap 29 ShutdownTimer Trap 18 Trap 31 ShutDura tion Trap 32 Temp o Force UM Client Shutdow n Rebo ot Main outle...

Page 31: ...ow n Rebo ot Outlet 2 4 2 4 Off On command Off On command is sent from UM Console or UM Vision 4 2 4 1 Main UPS outlet Utility Command Off From UM Vision with Off Delay 2 minutes 2 minutes Command On From UM Vision with On Delay 0 minutes Trap 29 Trap 31 Shutdown Duration Trap 32 UM Client Shutdown Rebo ot Main outlet 4 2 4 2 Programmable outlet 1 Trap 29 ShutoffTimer 1 Restart Delay 1 Trap 31 Sh ...

Page 32: ...gent by the user UM Console UM Vision Shutdown of all servers and possibility of UPS shutdown depending on its configuration after the Shutdown Duration of the SNMP agent During normal operation sending of a reboot command to the UPS toggle by the user Shutdown of all servers and possibility of UPS shutdown depending on its configuration after the Shutdown Duration of the SNMP agent and rebooting ...

Page 33: ...efault and then press Enter The card will disconnect itself after 3 minutes of inactivity The menu is in English only MGE UPS SYSTEMS SNMP Web agent Configuration menu Enter Password MGE UPS SYSTEMS SNMP Web agent Configuration menu 1 Agent Configuration 2 UPS Parameters 3 Access Control Table 4 Set NMS Parameters 5 Reset Configuration To Default 6 Reset Agent 0 Exit Please Enter Your Choice 5 1 1...

Page 34: ... default public 31 characters maximum 8 Community Read Write public Enter the name of the read write community This name is used by the UM Clients to subscribe to the table of notified Clients It is recommended to personalise this name Value by default public 31 characters maximum 9 HTTP Login Login MGEUPS Text field limited to 10 characters Enables secure access to the sections of the Configurati...

Page 35: ...tem Date yyyy mm dd 2003 06 10 Enables adjustment of the date 4 System Time hh mm ss 14 47 53 Enables adjustment of the time 0 Return to previous menu 5 1 3 Choice 3 Access control IP Address Community String Access 1 0 0 0 0 public NotAccess 2 0 0 0 0 public NotAccess 3 0 0 0 0 public NotAccess 4 0 0 0 0 public NotAccess COMMANDS 1 Modify Modify an entry of table 2 Reset Reset an entry to default...

Page 36: ...eturn to previous menu This menu enables subscription of the supervision stations receiving traps in the list of managers and configuration of the type of traps sent Comment It is unnecessary to add the UM Clients protecting your servers to this list as UM Clients are automatically added deleted 5 1 5 Choice 5 Restore default configuration Use this function to restore the card s factory configurat...

Page 37: ... Page 37 42 6 Maintenance 6 1 Software upgrade All information enabling 6 1 1 Card software upgrade using Mupgrade Windows 6 1 2 Card software upgrade via TFTP UNIX and Windows 6 1 3 Card software upgrade via the serial link Is available for download on the www mgeups com web site in the Download area embedded Software section ...

Page 38: ...status Fin défaut batterie UPS battery need to be replaced Batterie à remplacer UPS battery does not need to be replaced Batterie remplacée UPS at low battery Préalarme fin d autonomie UPS return from low battery Fin de préalarme UPS battery charger is not active Chargeur batterie arrêté UPS battery charger is active Chargeur batterie en marche UPS battery entering minimum condition Batterie en ch...

Page 39: ...leur UPS battery is unavailable Batterie indisponible UPS battery return from unavailable condition Batterie disponible UPS self test failed Autotest onduleur en défaut UPS self test succeeded Autotest onduleur terminé UPS passed battery test Test batterie terminé UPS failed battery test Test batterie en défaut UPS is on buck Onduleur en mode Buck UPS has returned from buck Mode Buck désactivé Out...

Page 40: ...enabling querying or updating of MIB from one or more agents and able to receive traps from these agents UM Client and UM Console are examples of managers MD5 Message Digest 5 Algorithm producing an output message from an input message of arbitrary length in the form of a replica or summary 128 bit message Intended for digital signature applications requiring large files to be compressed in total ...

Page 41: ...M Console UM Client UM Agent enabling protection of IT equipment connected to the TCP IP SNMP network Subnet mask Mask of bits used to identify and differentiate the network address and the equipment address in an IP address Normally the mask is automatically determined by the class of address which defines in a unique manner the network part equipment part division of the IP address Class A inter...

Page 42: ... E R Network Management Cards User Manual 34003676EN AA Page 42 42 UM Console Supervision and configuration software based on SNMP Used to configure UPS parameters or programmable outlet parameters load shedding with the UPS on battery power shutdown delay restart delay etc ...

Reviews: