![MGDVRs ACAP series Installation And User Manual Download Page 32](http://html.mh-extra.com/html/mgdvrs/acap-series/acap-series_installation-and-user-manual_1782983032.webp)
31
MGDVRs
w w w .
MGDVRs
. c o m
• ETC Setting
- Start backup timer:
Initiate “backup.exe” automatically upon the system startup. The backup
program icon will be placed on the system tray if launched successfully.
-
Overwrite when the disk is full:
If selected, assigned backup device will start overwriting when
it is full during automatic backup (Overwrites starting from the oldest backup data.)
Backup always starts from the end of the last backup session. (First time Backup will start from the
very beginning of recorded data)
<< Example >>
1) Backup (automatic) at 20:00 every day
- Data will be backed up at 20:00 every day until data for the day has been completely backed up.
2) Backup at 20:00 every Saturday
- Data will be backed up at 20:00 every Saturday until data for that week has been completely backed up.
5.7. Event Setup
Depending on events, different actions can be configured and performed.
• Beep:
Play Beep using sound card.
- Use PC Speaker: Play Beep using PC speaker (Sound card is not required)
• Mark:
Display Red dot on camera screen.
• Popup:
Display a single view Popup in DVR Main.
• TV-out:
Display the camera through Composite out for selected time period (in seconds)
• Second Screen:
If system has second monitor, display popup on the selected coordinate of the
second monitor.
• Remote Notify:
Notify to the Net client program (remote client software).
• Use Notify Schedule:
Use notify schedule (Camera – Schedule – Notify schedule).
After automatic Backup schedule has been configured,