40
‐
Control
Unit
E6L
/
Rev
6.11
9.
ACCESSORY
CARDS
MOUNTING
POSITION
CONTACT
OF
THE
PRESSU
‐
RE
GUARD
Figure
17.
SUPU
board
E6
‐
5
‐
08
S401
POSITION
Closing
Time
[s]
S401
POSITION
Closing
Time
[s]
S401
POSITION
Closing
Time
[s]
0
0
6
6
C
12
1
1
7
7
D
13
2
2
8
8
E
14
3
3
9
9
F
15
4
4
A
10
5
5
B
11
If
the
controller
is
equipped
with
service
terminal
E6
‐
6
‐
02/3E,
the
display
shows,
when
the
position
of
the
rotary
switch
is
changed,
for
a
moment
the
text
‘
A140
‘
and
after
that
the
set
time.
If
the
pressure
guard
has
stopped
and
closed
the
door
during
the
set
time,
the
display
shows
the
error
code
”
E20
”.
Simultaneously,
the
red
LED
H102
on
board
E6
‐
2L
will
be
flash
‐
ing.
If
any
of
following
functions
is
effective,
the
door
doesn’t
close,
but
remains
in
place:
•
STOP
circuit
is
broken,
•
the
beam
of
safety
photocell
is
broken,
•
an
obstacle
breaks
the
beam
of
the
safety
photocell,
•
the
door
is
on
hold
‐
to
‐
run
mode
in
the
closing
direction
or
•
OPEN
impulse
is
coming
from
the
opening
drive.
The
door
will
close
during
the
set
time,
when
the
beam
of
safety
photocell
becomes
solid
or
the
open
impulse
quits.
If
the
open
impulse
is
on
and
the
opening
contact
of
the
pressure
guard
has
stopped
the
door,
the
door
does
not
open
immedi
‐
ately
when
the
contact
of
the
pressure
guard
will
be
closed,
but
the
control
needs
a
new
open
impulse.
If
the
door
closes
under
the
control
of
pressure
guard
and
hits
a
safety
edge,
the
door
will
open.
The
control
has
rated
the
time
the
door
was
closing
before
the
safety
edge
impulse.
If
the
pressure
guard
indicates
again,
the
door
will
close
during
a
half
of
the
rated
time.
If
the
safety
edge
sends
a
new
impulse,
the
door
will
open.
The
control
has
rated
the
closing
time
again.
If
the
pres
‐
sure
guard
indicates
again,
the
door
will
close
during
a
half
of
the
last
rated
time.
The
to
‐
and
‐
fro
motion
continues
until
the
time
will
be
zero.
12/10