Position
switch
can
be
used
to
indicate
if
the
lock
of
the
latch
is
open.
The
position
switch
will
be
connected
to
the
screw
terminals
1
and
2
on
the
board
E6
‐
5
‐
06.
If
a
position
switch
is
not
installed,
or
not
in
use,
the
terminals
1
and
2
must
be
linked
with
short
‐
circuit
plug
to
enable
operation
of
the
drive
unit.
When
the
lock
latch
is
open,
the
contact
tip
of
the
posi
‐
tion
switch
closes
and
the
door
is
free
to
move.
When
the
door
gets
an
opening
impulse
from
closed
position,
the
relays
K3
and
K4
will
be
pulling
during
the
waiting
time
set
for
the
latch
to
open,
before
the
door
starts
to
move.
If
a
position
switch
for
the
latch
is
being
used,
the
contact
tips
of
this
switch
will
have
to
connect
the
terminals
1
and
2
together
within
the
waiting
time,
during
which
the
latch
reaches
its
full
open
position.
If
the
space
between
1
and
2
remains
open
after
the
waiting
time
is
over,
the
door
will
not
open.
In
this
situation
an
error
indication
will
be
produced
and
the
red
LED
H103
on
the
board
E6
‐
2L
will
start
flashing.
If
the
service
ter
‐
minal
E6
‐
6
‐
02/3E
is
used,
the
display
will
show
error
code
‘
E22
‘.
S401
POSITION
Waiting
time
[s]
before
locking
S401
ASENTO
Waiting
time
[s]
before
locking
0
0
8
5
1
0,5
9
10
2
1,0
A
15
3
1,5
B
20
4
2,0
C
25
5
2,5
D
30
6
3,0
E
45
7
4,0
F
60
S402
POSITION
Waiting
time
[s]
for
the
lock
to
open
S402
POSITION
Waiting
time
[s]
for
the
lock
to
open
0
0
8
5
1
0,25
9
10
2
0,5
A
15
3
1,0
B
20
4
1,5
C
25
5
2,0
D
30
6
3,0
E
45
7
4,0
F
60
9.
ACCESSORY
CARDS
12/10