Control
Unit
E6L
/
Rev
6.11
‐
37
The
functions
of
the
controller
in
various
exceptional
cases
has
been
explained
above
in
this
manual.
These
functions
can
be
modified
as
requested,
by
adding
program
board
E6
‐
5
‐
04
to
the
controller.
The
program
board
is
installed
according
to
the
above
instructions
on
to
a
free
bus
terminal.
The
parameters
are
programmed
from
switches
S403.1
,
S403.2,
S403.3
and
S403.4.
Check
the
‘ON‘
and
‘OFF‘
positions
of
switch
403
from
the
text
printed
on
the
switch.
Places
1,
2,
3,
4,
5
and
6
of
the
pin
terminal
must
be
left
in
their
factory
set
‐
tings,
1,
2,
3,
5
and
6
in
the
‘OFF‘
position
and
4
in
the
‘ON‘
position.
The
‘OFF‘
position
means
that
there
is
no
short
circuit
plug
and
the
‘ON‘
position
that
a
short
circuit
has
been
installed.
When
using
the
program
board,
it
must
be
left
in
the
control
in
order
to
maintain
the
desired
functions.
If
the
program
board
is
removed,
the
desired
programming
is
only
stored
until
the
next
power
failure.
After
the
power
failure,
the
control
does
not
remember
the
parameters
of
the
removed
program
board,
but
it
will
function
according
to
the
normal
parame
‐
ters.
CLOSING
ON
HOLD
‐
TO
‐
RUN
Closing
on
hold
‐
to
‐
run
is
set
with
switch
4
of
the
S403
.
•
ON:
the
controller
closes
the
door
on
hold
‐
to
‐
run
only
(the
close
button
must
be
pressed
through
the
entire
closing
movement).
No
automatic
closing.
•
OFF:
the
door
closes
normally.
If
the
controller
is
equipped
with
a
service
terminal,
the
display
shows,
when
the
mode
of
the
switch
is
changed,
for
a
mo
‐
ment
the
text
‘L210‘
and
after
that
‘OFF‘
or
‘ON‘
according
to
the
position
of
the
switch.
OPENING
ON
HOLD
‐
TO
‐
RUN
Opening
on
hold
‐
to
‐
run
is
set
with
switch
3
of
S403
.
•
ON:
the
controller
opens
the
door
on
hold
‐
to
‐
run
only
(the
open
button
must
be
pressed
through
the
entire
opening
movement).
•
In
position
‘OFF‘
of
the
switch,
the
door
opens
normally.
If
the
controller
is
equipped
with
service
terminal
E6
‐
6
‐
02/3E,
the
display
shows,
when
the
mode
of
the
switch
is
changed,
for
a
moment
the
text
‘
L200
‘
and
after
that
‘
OFF
‘
or
‘
ON
‘
according
to
the
position
of
the
switch.
SUPPRESSION
OF
AUTOMATIC
CLOSING
WITH
THE
STOP
BUTTON
In
a
normal
case
when
automatic
closing
has
been
set
in
the
control
and
the
STOP
button
is
pressed
while
the
door
is
in
its
open
position,
the
door
will
function
as
presented
on
page
9
of
this
manual.
The
said
function
can
be
changed
into
such
that
pressing
any
stop
button
makes
the
door
always
stay
open,
even
if
automatic
closing
were
set.
This
function
is
set
with
switch
2
of
S403
.
•
ON:
the
door
always
remains
in
its
open
position
at
an
impulse
from
any
of
the
existing
stop
buttons.
In
this
case
the
situation
is
cleared
by
pressing
the
close
button
or
open
‐
button,
or
by
giving
an
opening
impulse
to
the
board
for
auto
‐
matic
closing
with
quittance,
or
by
giving
a
closing
impulse
through
single
button
control,
if
this
has
been
programmed
to
close
from
open
position.
A
single
button
control,
which
has
been
programmed
for
only
opening
function,
will
not
clear
the
situation.
After
clearance,
the
door
will
close
and
be
back
in
normal
function,
so
that
next
time
the
door
will
close
automatically
from
its
open
position.
•
OFF:
the
door
function
is
normal.