34
Maintenance
Once installed and operating properly, the Mason-lite gas
appliance requires very little maintenance.
You should inspect the appliance, chimney, burner and control
annually for the following:
1. Excessive Sooting
- Some sooting of the logs is normal
and adds to the natural appearance of burned wood. If soot
accumulates, you may brush the soot off with a stiff brush.
Logs may also be cleaned by allowing them to heat up, then
spraying them with water where soot has accumulated.
2. Debris around the control
- Inspect the control and pilot to
be sure it is free of any dirt or debris.
3. Insects and burner blockage
- Check the burner ports
and the air-mixer, if present, to make sure they are free
from debris. Blocked burner ports and orifices may
result in poor flame distribution or flame at air mixer (if
equipped). Reference SOLUTION, to symptoms 2-4, of
Troubleshooting
.
Service
Log Placement
Log Placement
1
GML-24 shown
Figure 35
Figure 36
Figure 37
Figure 38
Figure 39
Figure 40
9
8
7
10
11
9
6
8
7
Start with the grate/burner assembly in place
Place back bottom log
Place front bottom log
Place back top logs (#8 and #9)
Place front top log (#7)
All logs in place