APPENDIX B
Save and Exit
Click to close this page, write the
configuration changes to FLASH memory, and reset the
i.LON 10 Ethernet Adapter. Configuration changes will take
effect upon reboot. After reboot, the Security page and the
MD5 Authentication key will no longer be available until a
security access reset is executed.
Exit Without Save
Click to close this page without saving
changes. Any changes made will be lost. The i.LON 10
Ethernet Adapter will not be reset and the Security page
and the MD5 Authentication Key will still be accessible if
they were before.
Display Factory Defaults
Click to set all i.LON 10
properties to factory defaults. The changes will not
propagate to the i.LON 10 until you click Save and Exit.
This button is only available the first time this Web page is
accessed after a security access reset.
Click Save and Exit when complete.
NOTE:
As soon as you click Save and Exit
the IP address of the i.LON 10 changes to
the value set on the Setup Web page. You need to
reset your PCs IP address to match the i.LON 10’s
subnet to access the Web page again.
I.LON 10 ETHERNET ADAPTER SECURITY
The i.LON 10 Ethernet Adapter institutes a number of
security measures:
MD5 Authentication
The i.LON 10 Ethernet Adapter uses
MD5 Authentication with all communications between it and
the LNS Server, requiring a 16 byte authentication key. See
Configuring the i.LON 10 Ethernet Adapter to Communicate
With An LNS Server for more information.
Security Web page
The i.LON 10 Ethernet Adapter
Security Web page allows you to password protect or
disable entirely access to the i.LON 10.
Security Access Reset
A security access reset is required
to view the MD5 authentication key, open the security
Web page, or reset the i.LON 10 Ethernet Adapter’s
configuration. A security access reset requires physical
access to the i.LON 10 hardware.
Security Access Reset
The following features of the i.LON 10 Ethernet Adapter are
available only after performing a security access reset:
■
Access to the MD5 Authentication Key on the setup
Web page (see i.LON 10 Ethernet Adapter Setup Web
page, earlier in this chapter).
■
Access to the Display Factory Defaults button on the
setup Web page.
■
Access to the security Web page (see i.LON 10 Ethernet
Adapter Security Web page, earlier in this chapter).
■
Access to the Perform Self-Test Web page. See the
i.LON 10 Ethernet Adapter User’s Guide for more
information.
■
Access to the firmware upgrade Web page.
i.LON 10 Ethernet Adapter Security Web Page
Access the Security Web page by clicking the Security link
from the Setup Web page (Figure B.1). This page is only
accessible after a security access reset.
Figure B.1. Accessing the Security Web Page in security access mode.