29
CHAPTER 3
The last dialog of the wizard will prompt you to shutdown
your computer. Select
No, I will restart my computer
later
.
Manually shutdown your computer from the Start menu
and install the Network Interface Card. When the Network
Interface Card is installed, restart your computer, then
launch RMS.
Launch RMS.
NOTE:
If RMS does not start successfully,
you will need to shut down RMS and
validate the Network Interface Card (covered in the
next section).
Validating the Network Interface Card
(Not necessary for i.LON only users)
To ensure that the Network Interface Card is properly set
up, as well as perform diagnostics, use the LonWorks Plug
‘n Play applet, found in the Control Panel. Follow these
steps to validate and check your card:
CAUTION:
You must click
OK
or
Apply
fol-
lowing these steps to ensure that the applet
has successfully communicated with the hardware
on-board your computer.
1. Inspect the
NI Application
drop-down box. If your
Network Interface Card is a PCI card, make sure
that NSIPCLTA is selected. If your card is a PCMCIA,
NSIPCC should be selected.
2. Click
Apply
to initialize and load the system image file
onto the card.
3. Click
Diagnostics
to launch the Diagnostics dialog and
test your card.
4. Click
Test
to request the connection status from your
card. You should see output similar to the messages
shown in Figures 3.1 and 3.2, indicating that your card
is working correctly.
NOTE:
If you get an error of any kind, click
Restart
and
Reset
to reset the card and
reload its firmware.
5. Click
OK
to exit the applet.