19
POWER KNOB
- The amount of transmitter signal output for each power setting
changes according to which frequency you are using:
Power Setting
Frequency__________________
982Hz
9.82kHz 82kHz
L-Low
0.3
watts
0.3
watts
0.15
watts
M-Medium
1
watt
1
watt
0.25
watts
H-High 3
watts
3
watts
3
watts
Sheath Fault Locating*
0.5 watts
0.35 watts
*Sheath Fault Locating - Set at this option for simultaneous sheath fault locating
capability. The SFL-2 A-Frame will receive the 4.8Hz sheath fault locating frequency;