![Metrotech 9800XT SFL2 Series Operation Manual Download Page 38](http://html.mh-extra.com/html/metrotech/9800xt-sfl2-series/9800xt-sfl2-series_operation-manual_1780080038.webp)
34
Triangulation Method.
As shown in
Figure 8-2
, (the point where the signal strength is a minimum) if the A-
Frame is positioned exactly on an equipotential circle, a perpendicular line from the
center of the A-Frame will pass through the fault. The intersection of any two such
perpendicular lines defines the fault location.
Paved Surface
Cable
Fault
Figure 8-2: Triangulation Method
To find an equipotential circle (see
Figure 8-3
) insert the A-Frame into the ground and
pivot around one spike. Rotate the A-Frame back and forth until the exact point is found
where the flashing arrows change direction. The A-Frame is now on an equipotential
circle and is perpendicular to the fault. By marking this line and repeating the process
with the A-Frame at another nearby location, the two lines will intersect or cross at the
fault.
Figure 8-3: Locating an Equipotential Circle