METRON Duo(+) User Manual Download Page 4

About

2

EV Charging station user manual

General

This manual is an important aid for ensuring the fault-free and safe operation of the device. The specifications 

in this manual apply only to the device stated in the product description. Read this manual before setting 

up the device.

Using this manual will help you to:
    •     avoid any risks for the user;

    •     become acquainted with the device;

    •     achieve optimum functioning;

    •     promptly detect and rectify faults;

    •     avoid any malfunctions due to improper installation;

    •     cut down on repair costs and reduce the number of downtimes;

    •     improve the reliability and increase the service life of the system;

    •     avoid causing harm to the environment.

These instructions are an important part of the product and must be retained for future reference. METRON 

accepts no liability for any damage resulting from non-observance of the information in this manual.

Safety

The device has been designed using state-of-the-art technology and is safe to operate.

Nevertheless, there may be residual risks associated with the device under the following circumstances:
    •     the device is not used as intended;

    •     non-compliance with the safety information given in this manual;

    •     the device is damaged;

    •     the device is not maintained properly;

    •     the device is modified or converted improperly;

    •     the maintenance work specified in this manual is not carried out in due time.

              Warning: 

Risk of death resulting from non-compliance with documentation! Any person authorized       

             to work on the system must have read and understood this manual, in particular the “Safety” chapter.

The electrical installation, initial operation and servicing of the device may only be performed by qualified 

electricians, who have been authorized by the operator.

Intended Use

The device may be used for the purpose described in “Product Description” on page 3 and in conjunction 

with the supplied and approved components. Any use exceeding the aforementioned shall be deemed 

unintended. METRON assumes no liability for damage resulting from non-intended use. Intended use also 

includes:
    •     compliance with all the information in this manual;

    •     carrying out of servicing tasks according to schedule.

The device may present hazards, if not used as intended.

Summary of Contents for Duo(+)

Page 1: ...ENGLISH EV CHARGING STATION USER MANUAL...

Page 2: ...ing However because continuous improvement is a goal at Metron we reserve the right to make product modifications at any time To communicate any inaccuracies or omissions in this document please send...

Page 3: ...stacles 9 Wall installation of the charging station 10 Electrical connection 11 Supply Voltage 11 Safeguarding and personal protection 11 Connecting the supply line 12 Operation 13 Setting the chargin...

Page 4: ...idual risks associated with the device under the following circumstances the device is not used as intended non compliance with the safety information given in this manual the device is damaged the de...

Page 5: ...which protects the main household fuse and allow solar SURPLUS charging where the house has a solar power plant installed The METRON charging station is meant to be used in private and semi public are...

Page 6: ...ufacturer Type Supply voltage and charging current settings Temperature operating range Country of origin Web page Serial number Production year Certification mark Protection class 1 2 3 Charging sock...

Page 7: ...indicator Push button Socket optionally with Type 2 Type 1 plug METRON Micro EVSE 1 or Micro EVSE 3 charge controller Charge controller power supply fuse Charging fuse Residual current protection devi...

Page 8: ...age frequency range from 90 V up to 270 V 50 60 Hz from 90 V up to 270 V phase voltage 50 60 Hz from 90 V up to 270 V phase voltage 50 60 Hz Cable length if ordered with plug and cable 5m premium qual...

Page 9: ...operational and storage max 95 without condensation max 95 without condensation max 95 without condensation Storage temperature From 40 C up to 70 C From 40 C up to 70 C From 40 C up to 70 C Minimum r...

Page 10: ...irements must be met Choosing the charging station location Warning Risk due to unsuitable environmental conditions installation locations Unsuitable ambient conditions and installation locations may...

Page 11: ...acles Maintain the specified minimum distances for unrestricted access during operation maintenance and repair The dimensions are given in mm 300 300 300 300 1 2 3 4 Insert the key in the keyhole Turn...

Page 12: ...of the charging station at a height up to the top edge of the casing of approximately 1 50 meters above the finished floor Make certain that charging station has been fitted firmly and securely A Nano...

Page 13: ...onal local regulations Ensure a clockwise rotating field for a three phase connection Safeguarding and personal protection Warning Danger to life by electric shock Residual current circuit breakers ty...

Page 14: ...r conductors 3 Check that the individual cores are properly connected and that the screws are tightened 4 Turn the reset lever to position to power the system Maximum conductor circumference in the po...

Page 15: ...4 kW 3x32 A 22 kW Duo 2 x 11 kW Duo 2 x 22 kW Number of LED blinks 1 2 3 4 5 6 7 8 Charging current power 2x3x6 A 2x4 1 kW 2x3x8 A 2x5 5 kW 2x3x10 A 2x6 9 kW 2x3x13 A 2x9 0 kW 2x3x16 A 2x11 0 kW 2x3x2...

Page 16: ...tions User can set the desired charging current and delay charging start User can turn on off solar SURPLUS charging if solar power plant is installed User can see all the real time measurements of ch...

Page 17: ...name ssid is reset to default value METRON Station 1 and forgotten password is reset to default value 12345678 but it s not yet activated To activate default WiFi password and default WiFi name you n...

Page 18: ...her household appliances might draw from the in house grid There are 3 options for installing Dynamic Power Control system main fuse protection A If there is 1 charging station in the house the curren...

Page 19: ...D slowly blinks The maximum available charging current depends on the following points Power rating of the charging station Features version of the charging station Current load capacity of the chargi...

Page 20: ...you cannot fix the error or fault ask a qualified electrician to check the charging station LED status Information Slow blinking immediately after turning on the charging station Blinks indicate last...

Page 21: ...t circuit the unit Cover neighbouring components that are under voltage and secure the danger area Maintenance Plan Caution Carry out the following maintenance work at the specified intervals Maintena...

Page 22: ...of old devices must comply with the common national and regional laws and regulations Ecological considerations must be taken into account Old devices and batteries cannot be disposed of with househo...

Page 23: ...ve been used in accordance with the user manual This limited warranty does not cover Damage due to improper use Damage done by incorrect setting Accidental or intentional damage Misuse abuse corrosion...

Page 24: ......

Reviews: