ENGLISH
EV CHARGING STATION
USER MANUAL
Page 1: ...ENGLISH EV CHARGING STATION USER MANUAL...
Page 2: ...ing However because continuous improvement is a goal at Metron we reserve the right to make product modifications at any time To communicate any inaccuracies or omissions in this document please send...
Page 3: ...stacles 9 Wall installation of the charging station 10 Electrical connection 11 Supply Voltage 11 Safeguarding and personal protection 11 Connecting the supply line 12 Operation 13 Setting the chargin...
Page 4: ...idual risks associated with the device under the following circumstances the device is not used as intended non compliance with the safety information given in this manual the device is damaged the de...
Page 5: ...which protects the main household fuse and allow solar SURPLUS charging where the house has a solar power plant installed The METRON charging station is meant to be used in private and semi public are...
Page 6: ...ufacturer Type Supply voltage and charging current settings Temperature operating range Country of origin Web page Serial number Production year Certification mark Protection class 1 2 3 Charging sock...
Page 7: ...indicator Push button Socket optionally with Type 2 Type 1 plug METRON Micro EVSE 1 or Micro EVSE 3 charge controller Charge controller power supply fuse Charging fuse Residual current protection devi...
Page 8: ...age frequency range from 90 V up to 270 V 50 60 Hz from 90 V up to 270 V phase voltage 50 60 Hz from 90 V up to 270 V phase voltage 50 60 Hz Cable length if ordered with plug and cable 5m premium qual...
Page 9: ...operational and storage max 95 without condensation max 95 without condensation max 95 without condensation Storage temperature From 40 C up to 70 C From 40 C up to 70 C From 40 C up to 70 C Minimum r...
Page 10: ...irements must be met Choosing the charging station location Warning Risk due to unsuitable environmental conditions installation locations Unsuitable ambient conditions and installation locations may...
Page 11: ...acles Maintain the specified minimum distances for unrestricted access during operation maintenance and repair The dimensions are given in mm 300 300 300 300 1 2 3 4 Insert the key in the keyhole Turn...
Page 12: ...of the charging station at a height up to the top edge of the casing of approximately 1 50 meters above the finished floor Make certain that charging station has been fitted firmly and securely A Nano...
Page 13: ...onal local regulations Ensure a clockwise rotating field for a three phase connection Safeguarding and personal protection Warning Danger to life by electric shock Residual current circuit breakers ty...
Page 14: ...r conductors 3 Check that the individual cores are properly connected and that the screws are tightened 4 Turn the reset lever to position to power the system Maximum conductor circumference in the po...
Page 15: ...4 kW 3x32 A 22 kW Duo 2 x 11 kW Duo 2 x 22 kW Number of LED blinks 1 2 3 4 5 6 7 8 Charging current power 2x3x6 A 2x4 1 kW 2x3x8 A 2x5 5 kW 2x3x10 A 2x6 9 kW 2x3x13 A 2x9 0 kW 2x3x16 A 2x11 0 kW 2x3x2...
Page 16: ...tions User can set the desired charging current and delay charging start User can turn on off solar SURPLUS charging if solar power plant is installed User can see all the real time measurements of ch...
Page 17: ...name ssid is reset to default value METRON Station 1 and forgotten password is reset to default value 12345678 but it s not yet activated To activate default WiFi password and default WiFi name you n...
Page 18: ...her household appliances might draw from the in house grid There are 3 options for installing Dynamic Power Control system main fuse protection A If there is 1 charging station in the house the curren...
Page 19: ...D slowly blinks The maximum available charging current depends on the following points Power rating of the charging station Features version of the charging station Current load capacity of the chargi...
Page 20: ...you cannot fix the error or fault ask a qualified electrician to check the charging station LED status Information Slow blinking immediately after turning on the charging station Blinks indicate last...
Page 21: ...t circuit the unit Cover neighbouring components that are under voltage and secure the danger area Maintenance Plan Caution Carry out the following maintenance work at the specified intervals Maintena...
Page 22: ...of old devices must comply with the common national and regional laws and regulations Ecological considerations must be taken into account Old devices and batteries cannot be disposed of with househo...
Page 23: ...ve been used in accordance with the user manual This limited warranty does not cover Damage due to improper use Damage done by incorrect setting Accidental or intentional damage Misuse abuse corrosion...
Page 24: ......