daeg Specifications 

SPO2 SIMULATION 

GENERAL 

  Factory installed, downloadable and user 

programmable R-curves, patient conditions 
and templates.  

  Probe signal and LED test 

 

ACTIVE PROBE SPO2 SIMULATION 

  O2 saturation range:  

35 

– 100 % 

  Simulation resolution:   

1% SpO2% 

  Simulation accuracy: 

  

±

 0.5 SpO2% 65-100% SpO2%

 

  

±

 1 SpO2% 30-64% SpO2% 

  Simulation repeatability: 

±

 0.2 SpO2% 

  Simulation rate:  

30 

– 300 bpm 

  Rate resolution:  

5 bpm  (sync. to ECG 

for 
  

 

“C-lock” testing) 

  Rate accuracy:   

±

 0.1% 

  Pulse amplitude 

– 100% of nominal 

  

 

pleth amplitude. 

  Amplitude resolution:  0-10 range, 1% 

   

 

10-100 range, 5% 

  Amplitude accuracy: 

30% amplitude 

±

1%. 

   

 

1-29% amplitude 

±

5%. 

  Pigmentation:    

Low, medium and high 

  Light repeater bandwidth:  

  

 

DC 

– 1MHz 

  Optical slew rate:  

50 mcd/ s  

  Light repeater dynamic range:  

  

 

1mcd + 13 dB 

– 60 dB 

  Receiver optical 3 dB bandwidth: 

  

 

600 

– 1050 nm. 

 

INSTALLED R-CURVES 

  BCI Oxipuls 
  Criticare 
  Nellcor 
  HP 
  Ohmeda 

 

ADDITIONAL R-CURVES

 

These are R-Curves that are available and 
can be uploaded using the PRO-Soft 

daeg 

software. 

 

  BCI Oxipulse 3301 
  Criticare 504 
  Dolphin 2100 
  HP/Philips 
  Massimo 
  Nellcor N-20, N-180, N-200, NBP-40, 

Symphony 

  Nonin 8500 & Marquette Apex 
  Novametrix Oxypleth 
  Ohmeda 3700, 3740 
  Welch Allen Propaq 

 

INSTALLED PATIENT CONDITIONS 

  Normal patient 
  Geriatric patient 
  Obese patient 
  Patient with weak pulse 
  Bradycardia 
  Tachycardia 

 

ARTIFACTS (ACTIVE PROBE ONLY) 

  Motion: 

 

0 - 4Hz 

  Ambient sunlight:  

Ambient, Sun  

  Interfering light:  

50Hz, 60Hz 

 

PROBE LED OPTICAL FREQUENCY 

  Frequency range:  

550 

– 1050 nm 

  Resolution:  

 

1nm 

  Accuracy:  

 

±

2% of range 

 

 

PROBE TEST 

Available with PTA-1 Probe Test Adapter Box -
Tests cable, photo sensors, Red LED and IR 
LED. 
 

  Interface for Nellcor and Ohmeda type sensors 

as standard.  

  Adapters for most major manufacturers 

available. 

 

  LED current continuity tests. 
  Photodiode response test with numerical 

display of  light transfer function, 0-100%  

  Advance cable test by detecting response 

glitches when flexing the cable.  

 
 

ECG SIMULATION -  
GENERAL 

The data below is related both to factory installed 
and downloadable waveforms. 

  Lead configuration:    

  

5 lead RL, RA, LA, LL, V1-6 

  Low level output amplitude:  

  

0.2-2mV, resolution 100  V 

  Low level output impedance:  

   

1000 ohm to RL 

  High level output amplitude:  

  

0.5V/mV of low level. 

  High level output impedance: 50 ohm 
  System amplitude accuracy: 

±

2% @1mV 

  System rate accuracy: 

± 

0.1% 

  System time resolution: 

10  s  

 (100 kHz maximum update rate) 

 

ECG OUTPUT 

The data below is related to factory installed 
waveform types. 

NORMAL ECG SINUS 

30 

– 300 BPM, resolution 5 BPM  

(synchronized with pleth wave) 
 
 

ACCESSORIES 

  Battery Eliminator 240V  or 115V 
  Batteries 
  User/Service Manual 

 
 

OPTIONS 

  PTA-1 Probe Test Adapter Box   
  SpO2 Probe Adapters (check availability) 
  Carrying case 
  Universal Snap-to-Banana Adapters 

 
 

GENERAL INFORMATION 

POWER SUPPLY 

  Power sources: 4 standard AA/LR6/MN-1500 

cells. 
230VAC/115VAC to 9vDC battery 
eliminator. 

  Power consumption:  

  

200 mA  w/o display backlight.  

  

400 mA w/full backlight. 

  Battery lifetime:  

  

12 h for alkaline cells without 

  

backlight. 

 

HOUSING 

High impact plastic case.  
 

DIMENSIONS 

  Height: 

237 mm/9.2” 

  Width: 

122 mm/4.8” 

  Depth: 

42 mm/1.6” 

 

WEIGHT 

With battery:  

0.6 kg/1.3 lb 

 

TEMPERATURE 

  Storage temperature: 

  

0/32  to +50/122   C/F 

  Operating temperature: 

  

+ 15/59  to +35/95

 

C/F 

HUMIDITY 

Operating humidity:  
  

10%  - 80% (non-condensing) 

 
DISPLAY 

Graphical LCD, with backlighting. 
 

CONNECTORS 

  9V DC power inlet (standard 2.1 mm power 

jack. 

  RS-232/C for PC or printer communication (9-

pin D-sub male) 

  1 probe connector (Redel 8-pin). 
  5 low level ECG outputs RA, RL, LA, LL and 

V1 (AHA color coded safety connector) 

  1 high level ECG output (standard phono jack).

 

 

RECOMMENDED PRINTERS 

HP DeskJet, Canon Bubble Jet or compatible. 
 

 

daeg

 SpO2 Analyzer 

Ordering Information 

Order no: 
12700

:

 

daeg

 SpO2 Analyzer

 

 

Accessories: 
12715

:

 

Finger Probe AFP-1 

17030

:

 

Battery Eliminator 

daeg

, 240V 

 

  or 

17027R

:

 

Regulated Battery Eliminator 115V 

 

17031

:  Battery package, 4-cells 

12710: 

User and Service Manual (CD)

 

 
Options: 
 
11150

:

 

Carrying case

 

12711

:

 

Probe Test Adapter Box 

12712

:

 

PRO-Soft 

daeg

 

12713

:

 

PRO-Soft 

daeg

, demo 

12714

:

 

User Manual PRO-Soft 

daeg 

17024

:

 

Universal Banana Adapter 

 

 

SpO2 Probe Adapters  

12761

:  BCI Compatible Direct SpO2 

12761N

: BCI Compatible 9-Pin SpO2 

12762

:  Criticare Compatible Direct SpO2 

12762N

: Criticare Compatible 9-Pin SpO2 

12764

:  Datascope Compatible Direct SpO2 

12764N

: Datascope Compatible 9-Pin SpO2 

12765

:  Datex Compatible Direct SpO2 

12765N

: Datex Compatible 9-Pin SpO2 

12766

:  Philips Compatible Direct SpO2 

12767

:  Invivo Compatible Direct SpO2 

12768

:  Nihon Kohden Compatible Direct SpO2 

12769

:  Nonin Compatible Direct SpO2 

12770

:  Novametrix Compatible Direct SpO2 

12773

:  Simed Compatible Direct SpO2 

12774

:  Spacelabs Compatible Direct SpO2 

12775

:  Sensormedics Compatible Direct SpO2 

12776

:  Masimo Compatible Direct SpO2 

 

 

 
 
 
 
 
 

Summary of Contents for daeg SPO2

Page 1: ...daeg SPO2 Simulator User Manual Version 1 15_2 Updated 22 01 2007...

Page 2: ...SICAL DAMAGE CAUSED BY MISUSE OR PHYSICAL ABUSE IS NOT COVERED UNDER THE WARRANTY Items such as cables and nonserialized modules are not covered under this warranty Recalibration of instruments is not...

Page 3: ...e g cables carrying cases auxiliary modules etc are not eligible for return or refund Only products returned within 90 days from the date of original purchase are eligible for refund credit In order...

Page 4: ...Calibration measurements are traceable to the National Institute of Standards and Technology NIST Devices for which there are no NIST calibration standards are measured against in house performance st...

Page 5: ...Table of Contents daeg Specifications 7 daeg Quick Start 9 Unit Setup 11 Operation 13 Troubleshooting 19...

Page 6: ...www metron biomed com 6 This page was intentionally left blank...

Page 7: ...curacy 2 1mV System rate accuracy 0 1 System time resolution 10 s 100 kHz maximum update rate ECG OUTPUT The data below is related to factory installed waveform types NORMAL ECG SINUS 30 300 BPM resol...

Page 8: ...www metron biomed com 8 This page was intentionally left blank...

Page 9: ...djust the active parameter using the yellow Up and Down arrow keys on the keypad then press enter to confirm the change 3 To change the simulation setting for oximeter model Make Ambient Light Pigment...

Page 10: ...www metron biomed com 10 This page was intentionally left blank...

Page 11: ...Refer to the diagram below when installing the batteries You will need to depress the tabs shown in the diagram below and remove the bottom dark gray piece of the chassis This will then expose the bat...

Page 12: ...www metron biomed com 12 This page was intentionally left blank...

Page 13: ...ing the F3 button The F2 button will move the cursor to the next parameter Using the Up and Down arrows will let you change the value of the selected parameter You will then need to press the yes ente...

Page 14: ...e F2 button will move the cursor to the next parameter Using the Up and Down arrows will let you change the value of the selected parameter You will then need to press the yes enter button to accept t...

Page 15: ...elect which test you wish to perform on the finger probe when you have the probe tester adaptor box attached Diode Test Pressing DIODE runs the test This test gives a descriptive message as to the con...

Page 16: ...ort in that element A Middle line is normal operation A Low indicates an open circuit Since this is a continuously running test it lets you flex you cable to check for intermittent failures Sensitivit...

Page 17: ...as follows Up and Down arrows control the cursor position yes enter increases the indicated value no clear decreases the selected value F1 decreases the selected SPO2 value F2 increases the selected S...

Page 18: ...www metron biomed com 18 This page was intentionally left blank...

Page 19: ...not match A Confirm that the Make is properly selected Confirm your selection by pressing the ENTER key after changing the value Q The monitor is not reading any values A Check all connections and ve...

Page 20: ...www metron biomed com 20 This page was intentionally left blank...

Reviews: