METRON daeg SPO2 User Manual Download Page 9

 

 

 

www.metron-biomed.com

 

daeg Quick Start 

 
 

daeg  Startup 

 

1. Connect daeg’s Finger Probe to the main daeg unit, 

and switch the daeg unit 

on

.  

 
The daeg must be powered by the 9VDC 400mA 
power supply or by 4 AA alkaline batteries loaded 
into the unit’s battery compartment.   
 

2. The version number of the firmware will be briefly 

displayed, followed by the first display screen 
(below). The unit is immediately outputting the 
simulation as displayed. 

 
3. Apply the oximeter’s sensor to the daeg finger 

probe. The sensor’s transmitter must be on the 
bottom (unlabeled) side of the daeg finger.

  

 
 
 
 
 
 
 
 
 
 

1. To adjust the simulation settings, use the 

F2

 

function key to select the “active” parameter. The 
active parameter is marked with an asterisk (*).  

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Note:

  Menu items at the bottom of the display are 

activated/accessed using the F1, F2, and F3 function 
keys. 

 
2. Adjust the active parameter using the yellow Up 

and Down arrow keys on the keypad, then press 

enter

 to confirm the change.    

                                                       

 

 
3. To change the simulation setting for oximeter 

model (Make), Ambient Light, Pigmentation, or to 
select an automated simulation sequence, select the 

F3

 function key to go to the second display screen. 

 
4. To access additional test and auxiliary functions, 

press the 

F1

 function key while in the first or 

second screen display.

 

 

 

Additional / Auxiliary functions include:  

  Alarm Tests, Print functions, Remote Control Operation, 

Probe Tests, and Simulation Setup.

 

                                        
 
 
 
 
 
                                   
 
   
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Release 

------------------

STATUS --------

--------Preset  : 

Manual 

SpO2  :    96  % 
Rate  :    60  BPM 
P.ampl 

:  100  % 

 
FUNC. 

           

 

       

displ-1

 

F1 

F2 

F3 

----------------- 

STATUS ----------------

Preset 

Manual 

SpO2 

:    96 

Rate 

:    60 

BPM 

P.ampl 

:  100 

%

 

 

FUNC.

 

    

 

        

displ-1

 

METR  N 

SpO2 Analyzer 

LED-test 
      Red 
      IR 

F1 

F2 

F3 

daeg 

no 

clear

 

yes 

enter

 

 

1

   

ABC

 

 .  ,  #  $ 

7    

STU 

 

template 

esc 

 

2

    

DEF

 

3    

GHI

 

4    

JKL

 

9    

YZ?

 

8   

VWX

 

0     

_- 

/

 

6   

PQR

 

5   

MNO

 

 

on 

off 

Battery Compartment 

daeg finger probe 

Label side to bottom.  

SpO2 sensor  

Red, IR light source 
introduced on unlabeled 
side of daeg finger.  

Daeg Operation / Simulation 

Summary of Contents for daeg SPO2

Page 1: ...daeg SPO2 Simulator User Manual Version 1 15_2 Updated 22 01 2007...

Page 2: ...SICAL DAMAGE CAUSED BY MISUSE OR PHYSICAL ABUSE IS NOT COVERED UNDER THE WARRANTY Items such as cables and nonserialized modules are not covered under this warranty Recalibration of instruments is not...

Page 3: ...e g cables carrying cases auxiliary modules etc are not eligible for return or refund Only products returned within 90 days from the date of original purchase are eligible for refund credit In order...

Page 4: ...Calibration measurements are traceable to the National Institute of Standards and Technology NIST Devices for which there are no NIST calibration standards are measured against in house performance st...

Page 5: ...Table of Contents daeg Specifications 7 daeg Quick Start 9 Unit Setup 11 Operation 13 Troubleshooting 19...

Page 6: ...www metron biomed com 6 This page was intentionally left blank...

Page 7: ...curacy 2 1mV System rate accuracy 0 1 System time resolution 10 s 100 kHz maximum update rate ECG OUTPUT The data below is related to factory installed waveform types NORMAL ECG SINUS 30 300 BPM resol...

Page 8: ...www metron biomed com 8 This page was intentionally left blank...

Page 9: ...djust the active parameter using the yellow Up and Down arrow keys on the keypad then press enter to confirm the change 3 To change the simulation setting for oximeter model Make Ambient Light Pigment...

Page 10: ...www metron biomed com 10 This page was intentionally left blank...

Page 11: ...Refer to the diagram below when installing the batteries You will need to depress the tabs shown in the diagram below and remove the bottom dark gray piece of the chassis This will then expose the bat...

Page 12: ...www metron biomed com 12 This page was intentionally left blank...

Page 13: ...ing the F3 button The F2 button will move the cursor to the next parameter Using the Up and Down arrows will let you change the value of the selected parameter You will then need to press the yes ente...

Page 14: ...e F2 button will move the cursor to the next parameter Using the Up and Down arrows will let you change the value of the selected parameter You will then need to press the yes enter button to accept t...

Page 15: ...elect which test you wish to perform on the finger probe when you have the probe tester adaptor box attached Diode Test Pressing DIODE runs the test This test gives a descriptive message as to the con...

Page 16: ...ort in that element A Middle line is normal operation A Low indicates an open circuit Since this is a continuously running test it lets you flex you cable to check for intermittent failures Sensitivit...

Page 17: ...as follows Up and Down arrows control the cursor position yes enter increases the indicated value no clear decreases the selected value F1 decreases the selected SPO2 value F2 increases the selected S...

Page 18: ...www metron biomed com 18 This page was intentionally left blank...

Page 19: ...not match A Confirm that the Make is properly selected Confirm your selection by pressing the ENTER key after changing the value Q The monitor is not reading any values A Check all connections and ve...

Page 20: ...www metron biomed com 20 This page was intentionally left blank...

Reviews: