7
I
NTRODUCTION
MS2220
S
CANNER
/A
VERY
S
CALE
D
ESIGN
S
PECIFICATIONS
Design Specifications
Scale Capacities
Capacity
:
kg unit
15 kg
lb. unit
30.0 lb.
Minimum Increment: kg unit
0.005 kg
lb. unit
0.01 lb.
Maximum Static Weight: kg unit
75 kg
lb. unit
150 lb.
Adjustments required: Calibration is required for scaled units.
Electrical
Voltage Supply:
2A @ +5.2V / 1A @ +12V
Operating Power: 11.9 Watts
Standby Power: 3.25 Watts
Operating Current: 1.5A @ 5.2V / .3A @ 12V
Standby Current: .44 A @ 5.2V / .08A @ 12V
DC Transformers: Class II; 5.2VDC @ 2A; 12VDC @ 1A
For Regulatory Compliance Information refer to pages 73 - 75.
Environmental
Operating Temperature: 0°C to 40°C (32°F to 104°F)
IP Rating: IP 55
Light Levels: 4842 Lux (450 footcandles)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% Relative Humidity, Non-Condensing
Contaminants: Sealed to resist airborne particulate contaminants.
Ventilation: None
Required
Specifications are subject to change without notice
.
Summary of Contents for StratosS MS2220
Page 1: ...METROLOGIC INSTRUMENTS INC MS2220 StratosS Scanner Avery Scale Installation and User s Guide...
Page 6: ...v...
Page 14: ...8 BASE MODEL CHARACTERISTICS MS2220 Scanner Avery Scale Components Figure 7 MS2220 Components...
Page 86: ......
Page 87: ......
Page 88: ...December 2006 Printed in the USA 0 0 0 2 0 3 5 C...