77
S
CANNER
T
EST
B
AR
C
ODES
Supplemental Tests
Display Software Numbers
The following codes
do not
require that the MS2xx0 to be in scale
program mode.
These codes are for test purposes only.
The following code will display software #’s on the 2-digit diagnostic display. The
lasers will be turned off while the numbers are being displayed. The first number
is the main decode processor software number. The second number is the I/O
processor’s software number. Since only 2 digits can be displayed at a time, the
following sequence is used as an example of what may be observed:
2-Digit
Display
Description of each sequentially displayed sets of digits.
(Example shown will represent: ‘ 15269’ ‘ 15138’)
x
1
=
The first digit of the five main decode processor software number
appears right justified.
5 2
=
The second and third digits.
6 9
=
The forth and fifth digits.
x x
=
Pause before next set of numbers.
x
1
=
The first digit of the five digit I/O processor software number
appears right justified.
5 1
=
The second and third digits.
3 8
=
The forth and fifth digits.
x
=
Blank / No Digit Displayed
After the last sets of digits are displayed, the scanner resumes scanning
operation. If the current interface does not use an I/O processor, the software
number may appear ‘ 0 00 00’. This capability exists in software 15269 and
later.
Display Software Number
³
9
9
8
0
6
2