background image

 

 

13 

S

CALE

/L

OAD 

C

ELL 

C

ONFIGURATION 

B

AR 

C

ODES

 

 

Dual Cable Scale Configuration Bar Codes 

 

Scale Protocols 

 

The following bar codes will change 

scale

 

parameters intended for a 

Dual Cable

 environment.  To place the

 scanner

 in 

Dual Cable

 mode, 

please refer to page 20. 

 

The MS2xx0 

must

 be in scale program mode to use these bar codes. 

 

Scale = EMEA 

Special Configuration

 

³

9

9

6

0

4

1

 

Set the scale to Avery EPOS protocol, 
kilograms, with a remote display, loose filter, 
no price computing, and scroll weight. 
 
Communication Port Settings: 

 2400 

Baud 

 

7 Data Bits 

 

1 Stop Bit 

 Even 

Parity 

 

 

 

 

 

Summary of Contents for Stratos MS2 Series

Page 1: ...METROLOGIC INSTRUMENTS INC MS2xxx Stratos Series Configuration Addendum...

Page 2: ...rior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Trademarks Metrologic is a registered trademark of Metrologic Instruments...

Page 3: ...g Configuration 10 Scale Protocols 11 Scale COM Port Settings Baud Rate 14 Scale COM Port Settings Data Bits Parity 16 Single Cable Scale Configuration Bar Codes Set Scale for Single Cable Communicati...

Page 4: ...sponses 38 BCC in POS communications 42 3 Scale Status Bytes 43 Scale Options 44 Remote Display 45 StratosSTATS 46 Additional POS Related Functions Scanner Beep on Weight Sent 49 Restrict In Store Cod...

Page 5: ...TABLE OF CONTENTS Continuous Mode 71 EAS Deactivation 72 Sensormatic ScanMax Pro 75 Scanner Test Bar Codes Supplemental Tests 77 Display Software Numbers 77 Contact Information and Office Locations 7...

Page 6: ...d and certified by local Weights and Measures authorities after the scale configuration process has been completed The scanner scale can not be placed in service until it is sealed and certified by th...

Page 7: ...seal is cut the unit cannot be place in service until it is calibrated sealed and certified by local Weights and Measures authority 3 Remove the M3 screw securing the switch cover in place Store the c...

Page 8: ...pment and be easily accessible Metrologic recommends using a switched AC outlet The switch should be located on the operator s side of the checkout counter in close proximity to the scanner scale to f...

Page 9: ...tion of the weighing mechanism of the scale version of this scanner is subject to federal state and local Weights and Measures statutes and regulations and can only be performed by authorized governme...

Page 10: ...Kilograms The following bar codes can be used to configure a Single or Dual Cable MS2xx0 The MS2xx0 must be in scale program mode to use these bar codes Scale Pounds 9 9 6 0 0 1 Set the scale measurin...

Page 11: ...remote display to show all scale activity A remote display must be plugged into the Scale RS485 to Display connector on the MS2xx0 see Figure 7 for this feature to function properly Figure 7 Location...

Page 12: ...be in scale program mode to use these bar codes The scale s filter setting allows the unit to withstand a certain amount of vibration from the checkout counter A stronger filter allows for more vibrat...

Page 13: ...tion The following bar codes can be used to configure a Single or Dual Cable MS2xx0 The MS2xx0 must be in scale program mode to use these bar codes Scale Medium Filter 9 9 6 0 0 6 Medium filter settin...

Page 14: ...configure a Single or Dual Cable MS2xx0 The MS2xx0 must be in scale program mode to use these bar codes These bar codes only affect the pole display Scale Scroll Settling Weight 9 9 6 0 1 0 Scroll th...

Page 15: ...ion The following bar codes are only used when the scale is in Dual Cable mode The MS2xx0 must be in scale program mode to use these bar codes Scale No Price Computing 9 9 6 0 0 8 Scale is not the pri...

Page 16: ...x0 must be in scale program mode to use these bar codes Scale EPOS Protocol 9 9 6 0 1 3 Set the scale RS232 protocol to Serial EPOS Communication Port Settings 2400 Baud 7 Data Bits 1 Stop Bit Even Pa...

Page 17: ...ual Cable environment To place the scanner in Dual Cable mode please refer to page 20 The MS2xx0 must be in scale program mode to use these bar codes Scale NCI ECR Protocol 9 9 6 0 1 5 Set the scale R...

Page 18: ...environment To place the scanner in Dual Cable mode please refer to page 20 The MS2xx0 must be in scale program mode to use these bar codes Scale EMEA Special Configuration 9 9 6 0 4 1 Set the scale...

Page 19: ...Scale Protocol bar code from page 11 or 13 is used the bar codes below must be scanned after the Scale Protocol bar code in order to be effective The MS2xx0 must be in scale program mode to use these...

Page 20: ...cale Protocol bar code from page 11 or 13 is used the bar codes below must be scanned after the Scale Protocol bar code in order to be effective The MS2xx0 must be in scale program mode to use these b...

Page 21: ...e Protocol bar code from page 11 or 13 is used the bar codes below must be scanned after the Scale Protocol bar code in order to be effective The MS2xx0 must be in scale program mode to use these bar...

Page 22: ...nvironment If a Scale Protocol bar code from page 11 or 13 is used the bar codes below must be scanned after the Scale Protocol bar code in order to be effective The MS2xx0 must be in scale program mo...

Page 23: ...r a Dual Cable environment If a Scale Protocol bar code from page 11 or 13 is used the bar codes below must be scanned after the Scale Protocol bar code in order to be effective The MS2xx0 must be in...

Page 24: ...MS2xx0 must be in scale program mode to use this bar code If your application requires single cable communication scan the following bar code to set the scale configuration to the single cable defaul...

Page 25: ...eive the scale data and the bar code data is sent via its own cable to a separate communication port Communication Port Settings 9600 Baud 8 Data Bits 1 Stop Bit No Parity There are two methods of con...

Page 26: ...to configure a Dual Cable MS2xx0 The following codes do not require that the MS2xx0 to be in scale program mode REWE 9 9 7 0 1 0 Dual Cable RS232 REWE Communication Port Settings 9600 Baud 7 Data Bit...

Page 27: ...g codes do not require that the MS2xx0 to be in scale program mode IBM 3 rd Generation Communication 9 9 9 9 5 2 When scanned the Stratos will operate as a table top scanner only Terminal configuratio...

Page 28: ...t require that the MS2xx0 to be in scale program mode MSS Global English 9 9 9 9 5 1 Scanner Scale Single Cable RS232 MSS Global Retail English Units Communication Port Settings 9600 Baud 7 Data Bits...

Page 29: ...g codes do not require that the MS2xx0 to be in scale program mode ISS45 English 9 9 9 9 4 9 Scanner Scale Single Cable RS232 ISS45 English Units Communication Port Settings 9600 Baud 7 Data Bits 1 St...

Page 30: ...es do not require that the MS2xx0 to be in scale program mode OPOS English 9 9 9 9 5 8 Scanner Scale Single Cable RS232 OPOS English Scale Defaults Communication Port Settings 9600 Baud 8 Data Bits 1...

Page 31: ...ot require that the MS2xx0 to be in scale program mode Retailix NCR English 9 9 9 9 5 6 Scanner Scale Single Cable RS232 Retailix NCR Communication English Communication Port Settings 9600 Baud 8 Data...

Page 32: ...bar codes can be used to configure a Single Cable MS2xx0 The following codes do not require that the MS2xx0 to be in scale program mode Retailix OPOS Metric 9 9 7 0 1 9 Scanner Scale Single Cable RS23...

Page 33: ...ng codes do not require that the MS2xx0 to be in scale program mode IT Retail English 9 9 7 0 0 8 Scanner Scale Single Cable RS232 IT Retail English Communication Port Settings 9600 Baud 7 Data Bits 1...

Page 34: ...that the MS2xx0 to be in scale program mode IBM Self Checkout System English 9 9 7 0 2 0 Scanner Scale Single Cable RS232 IBM Self Checkout System English Communication Port Settings 19200 Baud 7 Dat...

Page 35: ...codes do not require that the MS2xx0 to be in scale program mode Morrison s Tec Metric 9 9 7 0 2 3 Scanner Scale Single Cable RS232 Morrison s with Tec Display Metric Communication Port Settings 9600...

Page 36: ...do not require that the MS2xx0 to be in scale program mode IBM 3 rd Generation 46xx English 9 9 9 9 6 0 Scanner Scale Single Cable IBM 46xx RS485 English lbs Terminal Configuration IBM 4690 OS Termina...

Page 37: ...Cable MS2xx0 The following codes do not require that the MS2xx0 to be in scale program mode IBM OEM Full Speed USB English 9 9 9 9 6 2 Table Top Scanner Scale Single Cable IBM OEM Full Speed USB 4 Di...

Page 38: ...Speed USB Table Top Handheld The following codes do not require that the MS2xx0 to be in scale program mode Scanner 4B Handheld 3 1 6 4 3 0 Full Speed USB interface to 4B00h handheld usage Scanner 4A...

Page 39: ...able Top Handheld The following codes do not require that the MS2xx0 to be in scale program mode Scanner Scale 4A 6E Table Top 3 1 6 4 4 0 Full Speed USB interface to the 4A00h 6E00h table top scanner...

Page 40: ...atting Special Function ACK The following codes do not require that the MS2xx0 to be in scale program mode Enable Special Function ACK Answer 1 4 1 7 1 4 Answer simple special functions with ACK Disab...

Page 41: ...tting Prefix Suffix The following codes do not require that the MS2xx0 to be in scale program mode Use Protocol Prefix Suffix 1 4 1 7 1 5 Add protocol prefixes and suffixes to the bar code Program the...

Page 42: ...s do not require that the MS2xx0 to be in scale program mode No 3x 30 Answer 1 4 1 7 1 0 This bar code will inhibit all simple acknowledge 3x 30 answers to POS or OPOS commands 3x 30 Answer 1 4 1 7 0...

Page 43: ...lowing codes do not require that the MS2xx0 to be in scale program mode Spec Func Ans 3x30 1 4 1 9 1 4 Answer Special Function commands in the 3x 30 format as opposed to the Ack Nak which is the norm...

Page 44: ...e MS2xx0 to be in scale program mode Spec Func 30 30 Status 1 4 2 2 1 5 Returns Special Function commands in the 30 30 status as opposed to the 33 30 status Note Requires Spec Func Ans 3x 30 on page 3...

Page 45: ...t require that the MS2xx0 to be in scale program mode No Command Reject Answer 1 4 2 1 1 7 This bar code will ignore sending a command reject answer to the POS mode Send Command Reject Answer 1 4 2 1...

Page 46: ...lowing codes do not require that the MS2xx0 to be in scale program mode No Spec Func Answer 1 4 2 1 1 6 This bar code will ignore sending a special function response answer in POS mode Spec Func Answe...

Page 47: ...the MS2xx0 to be in scale program mode Skip BCC in messages 1 4 1 4 1 0 This bar code will tell the scanner to NOT expect or transmit the Block Check Character in all message transmissions Add BCC in...

Page 48: ...do not require that the MS2xx0 to be in scale program mode Enable 3 Scale Status Bytes 1 2 4 8 1 3 Required for applications where the host system display is the primary scale display and there is no...

Page 49: ...ds In order to work properly this bar code must be scanned AFTER scanning one of the English configuration bar codes found on pages 23 32 No Scale 1 4 1 4 0 7 Scan the No Scale bar code 1 If no scale...

Page 50: ...xx0 to be in scale program mode No Remote Display 1 4 0 9 0 2 When no remote display is installed scan the No Remote Display bar code AFTER scanning one of the configuration bar codes found on pages 2...

Page 51: ...ts StratosSTATS bar code data formatting active Bar code Attempt Interval to 0 5 seconds Time to find supplements code 128 to 0 3 seconds Use StratosSTATS monitor to test this output format When used...

Page 52: ...hese bar codes unless instructed by a Metrologic Representative Dual Stats Xmit 1 3 8 5 1 1 Allows non RS232 interfaces transmit normally without StratosSTATS and concurrently RS232 interfaces transmi...

Page 53: ...mode Do not scan these bar codes unless instructed by a Metrologic Representative Dual Xmit Carriage Return 1 3 8 5 1 2 This bar code enables a secondary carriage return suffix to be used only for the...

Page 54: ...in scale program mode Beep on Weight 1 4 1 9 1 7 Request scanner beep when a successful weight is sent This code should only be used for weight on demand applications If used with periodic weight req...

Page 55: ...odes do not require that the MS2xx0 to be in scale program mode Restrict In Store Codes 1 2 5 8 1 0 This bar code places tighter restrictions on in store codes These codes are EAN13 Sys2 UPCA Sys2 and...

Page 56: ...re that the MS2xx0 to be in scale program mode Scale Shadow Mode 1 4 2 2 1 7 This bar code sets the scale to the highest priority to allow for frequent scale POS commands This bar code is only to be u...

Page 57: ...ing codes do not require that the MS2xx0 to be in scale program mode Razz on Not On File 1 4 2 1 1 5 This bar code changes the audible to a razz signal when a Not On File command is received Beep on N...

Page 58: ...ale program mode Do not scan these bar codes unless instructed by a Metrologic Representative Horizontal High DOF 2 1 8 7 0 2 This bar code sets the DOF for all horizontal laser channels to High DOF w...

Page 59: ...the MS2xx0 to be in scale program mode Do not scan these bar codes unless instructed by a Metrologic Representative Horizontal Close DOF 2 1 8 7 2 2 This bar code sets the DOF for all horizontal lase...

Page 60: ...in scale program mode Do not scan these bar codes unless instructed by a Metrologic Representative Vertical High DOF 2 1 8 7 0 0 This bar code sets the DOF for the vertical laser channels to High DOF...

Page 61: ...that the MS2xx0 to be in scale program mode Do not scan these bar codes unless instructed by a Metrologic Representative Vertical Close DOF 2 1 8 7 2 0 This bar code sets the DOF for the vertical las...

Page 62: ...mode Auxiliary History Report 9 9 7 0 1 1 The Auxiliary port may be used to download or clear data to StratosSCHOOL The two commands that can be used are Upload Scanner Data and Clear Scanner Data wi...

Page 63: ...re the Stratos auxiliary port to accept a Metrologic scanner as the secondary scanner Enable Stratos Auxiliary Port 4 3 7 3 2 0 The auxiliary input port s data format must match the main output format...

Page 64: ...rologic Scanner Configuration sequence continued from previous page Set Stratos Format 4 3 7 5 2 0 Disable Secondary Scanner Beeper 3 1 8 5 0 5 Enable Communication Time Out 1 1 8 4 1 2 Disable CR Suf...

Page 65: ...AR CODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode No EAS Device 3 3 7 2 0 0 No EAS device is connected Factory Default Setting EAS...

Page 66: ...SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode EAS Device Type 2 3 3 7 2 2 0 EAS Device Type 3 3 3 7 2 3...

Page 67: ...62 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode EAS Device Type 4 3 3 7 2 4 0...

Page 68: ...R CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 0 seconds 8 4 6 0 0 0 Factory Default Setting EAS 1 second 8 4 6...

Page 69: ...64 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 2 seconds 8 4 6 0 0 2 0 0 EAS 3 seconds 8 4 6 0 0 3 0 0...

Page 70: ...65 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 4 seconds 8 4 6 0 0 4 0 0 EAS 5 seconds 8 4 6 0 0 5 0 0...

Page 71: ...66 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 7 seconds 8 4 6 0 0 7 0 0 EAS 10 seconds 8 4 6 0 1 0 0 0...

Page 72: ...7 SCANNER CONFIGURATION BAR CODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode EAS 15 seconds 8 4 6 0 1 5 0 0 EAS 20 seconds 8 4 6 0 2 0 0 0...

Page 73: ...re that the MS2xx0 to be in scale program mode EAS Digital Aux Port 1 4 6 1 0 0 The EAS signals use the RTS and CTS line of the Auxiliary RS232 In connector Factory Default Setting EAS Digital Host Po...

Page 74: ...n scale program mode EAS RS232 on Aux Port 1 4 6 1 1 1 This bar code allows the EAS RS232 signal to use the Tx Out and Rx In lines of the scanner to Aux RS232 In connector No EAS RS232 on Aux Port 1 4...

Page 75: ...cale program mode EAS RS232 on Host Port 1 4 6 1 1 2 This bar code allows the EAS RS232 signal to use the Tx Out and Rx In lines of the scanner to Host RS232 In connector No EAS RS232 on Host Port 1 4...

Page 76: ...that the MS2xx0 to be in scale program mode EAS Continuous Mode 1 4 6 1 1 5 When in continuous mode and the scanner is enabled the EAS will always be online to deactivate an EAS tag EAS Interlock Mod...

Page 77: ...MS2xx0 to be in scale program mode Blink Scan LED on Deactivation 1 4 6 1 1 3 The scanner will blink the scan LED upon receipt of an EAS deactivate acknowledge signal No Blink LED on Deactivation 1 4...

Page 78: ...t the MS2xx0 to be in scale program mode Fast Beep on Deactivation 1 4 6 1 1 4 Fast beep the scanner s beeper receipt of an EAS deactivate acknowledge signal No Beep on Deactivation 1 4 6 1 0 4 Do not...

Page 79: ...following codes do not require that the MS2xx0 to be in scale program mode Volume Switch Manual 1 4 6 1 1 6 The volume switch is used for manual EAS deactivation Volume Switch Normal 1 4 6 1 0 6 Volu...

Page 80: ...ust be connected to one of the RS232 scanner ports EAS Function 3 9 9 8 0 6 7 For Sensormatic ScanMax Pro get EAS s hardware version software version and serial number and transmit the information ove...

Page 81: ...RS232 EAS cable must be connected to one of the RS232 scanner ports EAS Function 1 9 9 8 0 6 5 For Sensormatic ScanMax Pro get EAS s deactivation count and transmit the information over the current sc...

Page 82: ...served 2 Digit Display Description of each sequentially displayed sets of digits Example shown will represent 15269 15138 x 1 The first digit of the five main decode processor software number appears...

Page 83: ...78...

Page 84: ...NOTES...

Page 85: ...NOTES...

Page 86: ......

Page 87: ......

Page 88: ...May 2008 Printed in the USA 0 0 0 2 0 3 4 E...

Reviews: