MI 2014 Cable Scanner
Section III Cable Scanner operation
22
Some typical TDR results
Lenght (open cable end)
Lenght
Lenght
Refl.2
Lenght (shorted cable end,terminated with remote)
no result ( cable lenght >300m or cable terminated)
Refl 1: problem at the
near end connector
Length and Reflections Test procedure
1. Select Length&Reflections function with rotary switch.
2. Check the selected cable type (refer to chapter 8 for more information).
3. Connect the tested cable to the instrument and press
.
If the test passed succesfully following items
are displayed (the lengths of measured
pairs should not differ for more then
5%±0.5m):
- the
sign
- the length of the displayed pair
length test successfully passed