8.7.2004
Rev. 1.0
Installation
18
5.3
Possible environmental interference
If the appliance is installed with its sides next to flammable walls (made of wood or sim-
ilar materials) or to heat-sensitive walls (made of plasterboard or similar materials), suit-
able protective measures should be taken to keep such walls undamaged. Therefore, apply
a coating to insulate the walls from radiative heat or keep a minimum clearance of 100
mm (4") from the side and back panels of the appliance.
If the appliance is installed in the immediate vicinity of other electric appliances, ensure
that they do not interfere with each other. They should all have independent power sup-
plies.
5.4
Preparing for installation
Check that the appliance is pre-set to use the gas family available at the place of use. If
the available gas is different, you will need to convert the appliance to use this other type
of gas. For directions, please refer to section
"Adjustment instructions"
below.
Check that the appliance is pre-set to operate on the voltage available at the place of use.
Should the available voltage rating be different, do not install the appliance.
5.5
Storage
If the appliance has been stored in a warehouse where room temperature is below 0°C
(32°F), it should be warmed up to at least +10°C (50°F) before switching it on.
5.6
Transporting the appliance
The best way to transport this appliance is inside its packing to protect it from outside
damage. After the appliance has been unpacked, use wooden spacers if you should need
to lift it up.
5.7
Unpacking the appliance
Prior to installation, remove all packaging materials from the appliance. Certain parts are
wrapped up in adhesive film, which should be carefully removed. Remove any glue traces
left on the appliance thoroughly using non-flammable solvents. It is forbidden to use abra-
sive substances.
5.8
Disposing of packaging materials
All packaging materials must be disposed of in compliance with applicable local regula-
tions in force where the appliance is being installed. Packaging materials should be sepa-
rated according to their types and delivered to specific collection sites. Ensure compliance
with environmental protection regulations.
Summary of Contents for 92/04 CG1P
Page 2: ...8 7 2004 Rev 1 0...
Page 4: ...8 7 2004 Rev 1 0...
Page 46: ...6SC00476 wiring diagram 96 04 CGEE 96 04 CGEE2P 96 04 CGEEP 3 N PE 400V 50 60 Hz...
Page 48: ...6SC00477 wiring diagram 94 04CGE 94 04CGE1P 94 04CGEP 3 N PE 400V 50 60 Hz...
Page 50: ...6SC00478 wiring diagram 94 04CGGE 94 04CGEE1P 94 04CGEEP 3 N PE 400V 50 60 Hz...
Page 52: ...6SC00480 wiring diagram 98 04CGE 98 04CGE2P 98 04CGEP 1 N PE 230V 50 60 Hz...
Page 74: ......