8.7.2004
Rev. 1.0
Installation
25
5.14
Gas technical specifications
The appliance should be started up at its rated output with the nozzles shown in
"Table 2:
burner specifications"
below. All the necessary nozzles are provided in a small bag to-
gether with the appliance. The nozzles of the main burners are marked in hundredths of
mm, while those of pilot flames have a reference number.
Table 2: specifications for burners and nozzles
C
D
E
Epot
Oven
Rated power (kW)
3,5
5,6
7
10
8.5
Minimum output (kW)
1.3
2.2
3.8
3.8
Natural gas consumption (m³/h)
G20
0,370
0,59
0.74
1.05
0.90
G25
0,43
0,69
0.86
1.23
1.05
G25.1
0,43
0,69
0.86
1.23
1.05
Liquid gas consumption (kg/h)
0,27
0,44
0.54
0.78
0.67
Town gas consumption (m³/h)
G110
G120
G20 20 mbar
Rated pressure (mbar)
20
Reduced pressure (mbar), minimum
Nozzles (1/100 mm)
Pilot flame
35
35
35
35
27
Max.
140
170R
185R
240
255
Min.
R
R
R
R
Primary air distance (mm)
0
3
4
4
1
G25 20 mbar
Rated pressure (mbar)
20
Reduced pressure (mbar), minimum
Nozzles (1/100 mm)
Pilot flame
35
35
35
35
27
Max.
150
185R
200R
265
245
Min.
R
R
R
R
Primary air distance (mm)
0
3
4
4
1
G25 25 mbar
Rated pressure (mbar)
25
Reduced pressure (mbar), minimum
Nozzles (1/100 mm)
Pilot flame
35
35
35
35
27
Max.
140
170R
185R
255
225
Min.
R
R
R
R
Primary air distance (mm)
0
3
4
4
1
G30/31 28/37 mbar
G30/31 30 mbar
G30/31 30/37 mbar
Rated pressure (mbar)
28 / 30 / 37
Reduced pressure (mbar), minimum
Nozzles (1/100 mm)
Pilot flame
20
20
20
20
19
Max.
90
115
130
155
145
Min.
45
65
80
80
Primary air distance (mm)
2,5
6
OPEN
OPEN
2
Summary of Contents for 92/04 CG1P
Page 2: ...8 7 2004 Rev 1 0...
Page 4: ...8 7 2004 Rev 1 0...
Page 46: ...6SC00476 wiring diagram 96 04 CGEE 96 04 CGEE2P 96 04 CGEEP 3 N PE 400V 50 60 Hz...
Page 48: ...6SC00477 wiring diagram 94 04CGE 94 04CGE1P 94 04CGEP 3 N PE 400V 50 60 Hz...
Page 50: ...6SC00478 wiring diagram 94 04CGGE 94 04CGEE1P 94 04CGEEP 3 N PE 400V 50 60 Hz...
Page 52: ...6SC00480 wiring diagram 98 04CGE 98 04CGE2P 98 04CGEP 1 N PE 230V 50 60 Hz...
Page 74: ......