8.7.2004
Rev. 1.0
Adjustment instructions
30
6.2
Replacing the open fire pilot flame nozzle
•
Carry out the first step of the chapter 6.1;
•
unscrew the sealing screw (item 7 in Fig. 12) using a 11 mm wrench and remove it;
•
unscrew the nozzle (item 6) using a screw-driver and remove it;
•
install the appropriate nozzle and tighten it (see "Table 2: specifications for burn-
ers";
•
adjust the pilot flame air by turning the ring in item 4 in fig.12;
•
the pilot flame will wrap around interely the thermocouple and its color will be
blue. Otherwise, check that the appropriate nozzles have been installed.
Fig. 12
1.
Thermocouple fixing nut
2.
Pilot flame top
3.
Thermocouple
4.
Air sleeve ring
5.
Pilot flame assembly
6.
Nozzle
7.
Sealing screw
8.
Bicone union
Summary of Contents for 92/04 CG1P
Page 2: ...8 7 2004 Rev 1 0...
Page 4: ...8 7 2004 Rev 1 0...
Page 46: ...6SC00476 wiring diagram 96 04 CGEE 96 04 CGEE2P 96 04 CGEEP 3 N PE 400V 50 60 Hz...
Page 48: ...6SC00477 wiring diagram 94 04CGE 94 04CGE1P 94 04CGEP 3 N PE 400V 50 60 Hz...
Page 50: ...6SC00478 wiring diagram 94 04CGGE 94 04CGEE1P 94 04CGEEP 3 N PE 400V 50 60 Hz...
Page 52: ...6SC00480 wiring diagram 98 04CGE 98 04CGE2P 98 04CGEP 1 N PE 230V 50 60 Hz...
Page 74: ......