Gas technical specifications
The appliance should be started up at its rated output with the nozzles shown in
"Table 2:
burner specifications"
below. All the necessary nozzles are provided in a small bag to-
gether with the appliance. The nozzles of the main burners are marked in hundredths of
mm, while those of pilot flames have a reference number.
Table 2: burner specifications
C
D
Oven
Rated output (kW)
3.5
5.6
7.9
Minimum output (kW)
0.9
1.8
/
Natural gas consumption (m³/h)
G20 0.370
0.593
0.836
G25
0.431
0.690
0.973
G25.1
0.431
0.690
0.973
Liquid gas consumption (kg/h)
0.274
0.438
0.618
Town gas consumption (m³/h)
G110
G120
G20 20mbar
Rated pressure (mbar)
20
Reduced pressure (mbar), minimum
1
1.8
Nozzles (1/100 mm)
Pilot flame
35
35
27·2
Max.
140
170
210
Min.
Primary air distance (mm)
0
3
0
G25 20mbar
Rated pressure (mbar)
20
Reduced pressure (mbar), minimum
1
1.8
Nozzles (1/100 mm)
Pilot flame
35
35
27·2
Max.
150
185
240
Min.
Primary air distance (mm)
0
3
15*
G25 25mbar
Rated pressure (mbar)
25
Reduced pressure (mbar), minimum
1.5
2.5
Nozzles (1/100 mm)
Pilot flame
35
35
27·2
Max.
140
170
220
Min.
Primary air distance (mm)
0
3
15*
G30/31 28/37 mbar
G30/31 30 mbar
G30/31 30/37 mbar
Rated pressure (mbar)
28 / 30 / 37
Reduced pressure (mbar), minimum
Pilot flame
20
20
27·2
Nozzles (1/100 mm)
Max.
90
115
145
Min.
45
65
/
Primary air distance (mm)
2.5
6
22
Summary of Contents for 72/02CG
Page 2: ......
Page 4: ...30 7 2003 Rev 1 0...
Page 10: ...2 9 2003 Rev 1 0 Safety 4...
Page 14: ...2 9 2003 Rev 1 0 Functional description 8...
Page 34: ...2 9 2003 Rev 1 0 Installation 28...
Page 44: ...2 9 2003 Rev 1 0 Adjustment instructions 38...
Page 48: ...2 9 2003 Rev 1 0 Troubleshooting 42...
Page 50: ......
Page 51: ...SC00414 wiring diagram 74 02CGE 76 02CGE 3 N PE 400V 50 60 Hz...
Page 52: ...6SC00473 wiring diagram 74 02CGE 76 02CGE 74 02CTGE 3 PE 230V 50 60 Hz...
Page 53: ...SC00415 wiring diagram 76 02CGGE 1 N PE 230V 50 60Hz...
Page 54: ...SC00413 wiring diagram 76 02CGEE 3 N PE 400V 50 60Hz...
Page 56: ...2 9 2003 Rev 1 0 Technical specifications 74 Installation and connection drawing 72 02CG...
Page 57: ...2 9 2003 Rev 1 0 Technical specifications 75 Installation and connection drawing 72 02TCG...
Page 58: ...2 9 2003 Rev 1 0 Technical specifications 76 Installation and connection drawing 74 02CG...
Page 59: ...2 9 2003 Rev 1 0 Technical specifications 77 Installation and connection drawing 74 02TCG...
Page 60: ...2 9 2003 Rev 1 0 Technical specifications 78 Installation and connection drawing 74 02CGG...
Page 61: ...2 9 2003 Rev 1 0 Technical specifications 79 Installation and connection drawing 74 02CGE...
Page 62: ...2 9 2003 Rev 1 0 Technical specifications 80 Installation and connection drawing 76 02CG...
Page 63: ...2 9 2003 Rev 1 0 Technical specifications 81 Installation and connection drawing 76 02TCG...
Page 64: ...2 9 2003 Rev 1 0 Technical specifications 82 Installation and connection drawing 76 02CGG...
Page 65: ...2 9 2003 Rev 1 0 Technical specifications 83 Installation and connection drawing 76 02CGGE...
Page 66: ...2 9 2003 Rev 1 0 Technical specifications 84 Installation and connection drawing 76 02CGE...
Page 67: ...2 9 2003 Rev 1 0 Technical specifications 85 Installation and connection drawing 76 02CGEE...
Page 72: ......