Event Management E-mail, LOGGER, IPWatchdog
LOGGER
The input event is stored in the log on the SD card of the switch.
Switches support sending e-mails via SMTP server (port 25).
Example:
If IP watchdog 8 detects a disconnection, the switch sends an e-mail to address 2.
&
We recommend using IPLOG PLCs or G-Series switches to support secure e-mails.
PoE and IP Watchdog
Event management switches allow you to monitor arp queries of 8 IP cameras.
Settings
IP camera specifications in the "Extension/IP watchdog" menu
IP address
- IP address of the camera
Retry count
- number of arp
unsuccessful / successful queries before
the set action is run
Restart PoE
- restart PoE power supply
Restart PoE timeout (s) -
time for which
the PoE power supply will be switched off
(ensuring the discharge of capacitors in
the PoE device). If the IP camera is not
powered from PoE, but for example from
24VAC, a restart can be done via a relay.
Example:
If the IP Watchdog 4 detects a disconnection, the switch relay closes for the set time.
Example:
Receiving a TCP pattern initiates a restart of the PoE power supply on P2.