background image

 

3

 

 

This equipment is for indoor use only 

 

2

 

SYMBOL DEFINITIONS 

 

Symbol 

Definition 

 

Power On/Off 

      

 

Cycle Mode 

 

Timer 

 

     

 

Vacuum  

 

 

Pressure 

 
 

3

 

SPECIFICATIONS

 

 

Size 

152mm X 165mm X 178mm 
(6” X 6.5” X 7”) 

Weight 

1.2 kg (2.6 lbs) 

Input Voltage 

24VDC 

Rated Power 

10W 

Air Input 

100 psi (6.9 bar) Max. 

Pollution Degree 

II 

Installation Category 

Indoor Use 

Altitude up to 2,000m (6,562ft) 

Operating Temperature 

0˚C to 50˚C (32˚F to 122˚F) 

Storage Temperature 

-10˚C to 60˚C (14˚F to 140˚F) 

Max. Relative Humidity 

80% for temperature up to 31˚C (87.8˚F) Decreasing 
linearly to 50% relative humility at 40˚C (104˚F) 

Air Output 

DX-350 = 0-100 psi (0-6.9 bar)  
DX-355 = 0-15 psi (0-1.03 bar)  

Vacuum 

406mm (16”) of Hg 

Timer 

0.008-60.000 seconds 

Cycle Mode 

Timed, Interrupt, Teach, Purge  

Timing Repeat Tolerance 

+/- 0.001% 

Cycle Rate 

1,200 cycles/min. 

LCD 

20 X 4 display segments 

 

 

4

 

4

 

FEATURES 

Figure 1.0  

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

Items 

Description 

Power Button 

 

Mode Button

 

Reset Button 

Display 

Air Pressure Regulator 

Pulsed Air Outlet   

Vacuum Control

 

Setup Control Knob 

Foot Switch Receptacle 

10 

Receiver Head air hose holder 

11 

Power Receptacle 

12 

 I/O Connection 

13 

Exhaust Port 

14 

Accessory Air Outlet 

15 

Air Inlet  

16 

Cord Lock 

Summary of Contents for DX-355

Page 1: ...following actions Making changes to equipment that has not been recommended in the User Guide Using incompatible or damaged replacement parts Using unapproved accessories or auxiliary equipment 1 2 Safety Precautions Do not operate this unit in excess of maximum ratings settings Always wear appropriate personal protective clothing or apparel Use only the following power adaptor models PSA15R 240P ...

Page 2: ...0 for temperature up to 31 C 87 8 F Decreasing linearly to 50 relative humility at 40 C 104 F Air Output DX 350 0 100 psi 0 6 9 bar DX 355 0 15 psi 0 1 03 bar Vacuum 406mm 16 of Hg Timer 0 008 60 000 seconds Cycle Mode Timed Interrupt Teach Purge Timing Repeat Tolerance 0 001 Cycle Rate 1 200 cycles min LCD 20 X 4 display segments 4 4 FEATURES Figure 1 0 Items Description 1 Power Button 2 Mode But...

Page 3: ...Depress Foot switch to activate timed dispensed cycle 6 3 Teach Mode Setting In the teach mode the unit will accumulate time as long as the foot switch is depressed This is helpful in determining dispense time required when dispense output is unknown 1 Press the Mode button 2 to select TEACH mode 2 Press and release the reset button 3 until the dispense time 0 000S 3 Press and hold down Foot switc...

Page 4: ...he following recommendations should be followed 1 Make certain air supply is clean and dry 2 Avoid turning barrels upside down or laying barrel so that material may run through air line to internal components 3 Avoid connecting the unit to excessive moisture or solvent saturation 4 Avoid connecting air supply exceeding 100 psi 6 9 bar for the DX 350 and 15 psi 1 03 bar for the DX 355 5 Use only Am...

Page 5: ...DC range and a maximum of 250 mA Note During the dispense cycle pin 3 will be grounded Please make sure the external device your machine that controls the dispenser controller has the same ground as the DX 350 355 controller Pin 7 8 and 9 Available Chasis Ground To initiate a dispense cycle with contact closure When low pressure alarm is triggered Pin 4 is grounded When low pressure alarm is turne...