background image

Quality Water International 

®

Owner’s Manual & Installation Guide

Version 1.0

®

Summary of Contents for MAXIMIZER 97 Series

Page 1: ...Quality Water International Owner s Manual Installation Guide Version 1 0...

Page 2: ...bacterial iron algae sulfur tannins organic matter or other unusual substances then unless the appliance is represented as being capable of handling these substances in the appliance specifications o...

Page 3: ...8 11 Valve Overview 12 Bypass Valve Overview 12 Blending Dial Overview 12 Touch Screen Controller 13 Setting The Touch Screen Controller 13 Service Settings 14 17 Customer Settings 18 Operating Modes...

Page 4: ...make specification and product changes without prior notice This manual is for installation operation and maintenance of the following water conditioning appliance model s Owner Information If your s...

Page 5: ...water is not being used If there is more than one appliance allow two hours between each regeneration 5 If dirt sand or large particles are present in the water supply the appropriate Hague filter ca...

Page 6: ...being capable of treating these contaminants in its specifications The appropriate Hague Water Filter can address these water shortcomings Iron A common problem found in many water supplies is iron It...

Page 7: ...nlet of the water heater Do Not 1 Do not install if checklist items are not satisfactory see Checklist Before Installation 2 Do not install if the incoming or outlet piping water temperature exceeds 1...

Page 8: ...ution Do not plumb the appliance in backward F Place the appliance in the desired location using Figure 1 as a guide The diagram in Figure 1 applies to basement slab crawl space and outside installati...

Page 9: ...ne carries away the backwash water as part of the regeneration cycle A Connect the drain line to the drain end cap with a minimum 1 2 inch I D tubing not supplied The size cannot be reduced Note If th...

Page 10: ...nual regeneration see Setting Touch screen Controller and inspect for proper operation Allow the appliance to draw all the water out of the brine cabinet until the air check draw tube sets 8 10 minute...

Page 11: ...ers return the gas cock to On D Open a cold water tap and allow the appliance to flush for 20 minutes or until approximately 72 gallons 270 liters have passed through the appliance This procedure is r...

Page 12: ...remely hard water is present the blending valve may only need to be cracked open Where the incoming water has relatively low levels of hardness the blending valve will need to be opened further The bl...

Page 13: ...ure that the bottom of the controller is firmly locked onto the four tabs on the top of the drive end cap assembly Figure 3 Smart Touch Controller Customer Settings Gallons Remaining Message Status In...

Page 14: ...or No see History in next section OK to continue Language Select the desired language English Fran ais Espa ol Deutsch Italiano OK to continue Total Regenerations Displays number of regenerations For...

Page 15: ...ber 52 to 9999 Grains or 788 to 6999 gm OK to continue Backwash 2 Minutes Second backwash cycle duration Preset 005 0 0 to 999 9 OK to continue Salt Select Regenerant Sodium or Potassium OK to continu...

Page 16: ...o 999999 OK to continue H Number of People Enter number of people in the household 1 to 50 OK to continue H Software V Software version number For Reference Only OK to continue Service Settings Histor...

Page 17: ...9 ppm mg L OK to continue H Total Regenerations Displays number of regenerations Value does not reset For Reference Only OK to continue H Save History Choose to save history Yes or No OK to continue H...

Page 18: ...for AM PM hh mm OK to continue Regeneration Time Mode 1 Days of Week Only see Operating Modes section OK to continue People Enter number of people in the household 1 to 50 OK to continue Customer Set...

Page 19: ...s of the week When the appliance is in the Patented Savematic Demand Delayed mode it will regenerate based on the actual water usage and the total capacity of the appliance The time that the regenerat...

Page 20: ...lb grams salt kg 5 400 1 350 0 5 2 Salt Setting Backwash 1 minutes 01 0 Brine Rinse minutes 22 0 Backwash 2 minutes 03 0 Capacity grains salt lb grams salt kg 13 700 3 888 1 4 3 Salt Setting Backwash...

Page 21: ...roller 1 3 90837 Bypass Nut Gasket 2 4 90259 1 inch CPVC CTS Adapter 2 90254 3 4 inch Copper Adapter optional 90256 3 4 inch PVC Adapter optional 90258 1 inch Copper Adapter optional 5 90251 Bypass Nu...

Page 22: ...IO Adapter 2 5 97500 Media Tank Assembly 1 6 97005 97MM Support Panel Black 1 7 90828 O Ring Small End Cap 1 8 90819 O Ring End Cap 1 9 54202 Drive Piston Slide 1 10 93870 Screw End Cap 2 11 93848 3 8...

Page 23: ...ne cabinet The small hole in the injector nozzle is the one that creates the injection stream that enters the throat It is important that this hole is round undamaged and clear of debris If this hole...

Page 24: ...d 1 inch CPVC CTS adapter 90259 Make sure the O Ring is between the bypass valve assembly and the flange on the cpvc adapter The O Ring seal areas at the main control valve inlet and outlet must be sm...

Page 25: ...vertightened it can damage the O Ring and cause a permanent leak 8 90828 O Ring 1 9 90264 O Ring 1 10 90809 Screw 1 11 93860 Turbine Sensor Wire Assembly w Cap 1 Picks up the magnetic field from the t...

Page 26: ...generated by the motor to the rest of the drive system If the drive system becomes jammed this opening can become rounded causing the gear to turn but not the piston slide cam If this occurs clear th...

Page 27: ...the end cap housing 10 90818 Screw 4 11 93699R JG Brine Valve Housing Assembly 1 Attaches to the drive end cap with two 3 4 inch self tapping screws and has one O Ring seal The O Ring is used as axia...

Page 28: ...atic O Ring on the brine piston If any defects are detected by visual inspection repair or replace as needed 4 90843 5 gpm Flow Control 1 The flow button has two distinct and different sides One is fl...

Page 29: ...the o ring stays in the groove in the end cap If misaligned the o ring can become pinched and leak 3 H2086 Drain Line Flow Control 1 The drain line flow control DLFC maintains a constant plus or minu...

Page 30: ...18 15 Quality Water International Assembly and Parts 3 1 2 Part Description Qty 54900 Entire Safety Shutoff Assembly 1 54226 Safety Shutoff 1 2 56018 Float 1 3 54190 Air Check Draw Tube 1 Safety Shuto...

Page 31: ...utoff Valve Elbow Figure 14 Safety Shutoff Valve Elbow Assembly Note The nut gripper and retainer sleeve are a three piece assembly that can come apart if removed from the elbow body Parts must be rea...

Page 32: ...ting number Not metering water Flow should be indicated with water usage If no flow see below Blending dial is open Make sure blending dial is closed No Flow Is Indicated When Water Is Flowing The byp...

Page 33: ...or replace injector Replace throat if removed Not Regenerating In Proper Sequence Magnet disk defective Replace magnet disk Defective controller Replace controller Salty Water Plugged injector Replace...

Page 34: ...34 Maximizer 97 Owner s Manual OR 05 18 15 Quality Water International Notes Notes...

Page 35: ...otal length of regeneration min gal L 25 20 76 2 Salt Setting Total length of regeneration min gal L 27 5 21 79 3 Salt Setting Total length of regeneration min gal L 31 5 23 87 4 Salt Setting Total le...

Page 36: ...2015 97905 Version 1 0 OR 05 18 15 Quality Water International USA Made In Hague Quality Water International 4343 S Hamilton Road 614 836 2115 Groveport OH 43125 www haguewater com...

Reviews: