17
OPERATION MANUAL
5.3 FILLING THE HYDRAULIC OIL
When filling the oil the ram must be in the FULLY UP POSITION
before any filling of the oil takes place. Failure to do so will cause overflowing of the oil, creating
a slip hazard.
Checking the hydraulic oil:
The hose must not be remove when checking
the oil. To check or fill the pump, open the oil
filler cap on the top of the reservoir. (Fig.5.1).
The oil should be filled to the bottom of the
thread. If the oil is not adequate, fill with 32#
hydraulic oil as necessary. Once filled, then
replace the filler cap, and bleed the air from the
hydraulic system as described on page 13.
Metalmaster have technical support engineers
available for service.
F
ig
.5.1
Filler Cap