Technical specifications SMART EKO-CARBON
(USER/INSTALLER)
Tab. 8.1 Technical specifications SMART EKO-CARBON
PARAMETERS
UNIT
TYPE OF BOILERS
SMART EKO-CARBON 16
SMART EKO-CARBON 20
SMART EKO-CARBON 25
SMART EKO–CARBON 30
Nominal thermal output
[kW]
16
20
25
30
Boiler power range
[kW]
4,8 - 16
6 - 20
7,5 - 25
9 - 30
Heating surface
[m
2
]
1,63
2,0
2,6
3,08
Boiler water capacity
[L]
48
60
71
80
Maximum working pressure
[bar]
3
3
3
3
Maximum working temperature
[°C]
95
95
95
95
Test pressure
[bar]
4,5
4,5
4,5
4,5
Boiler class
-
5
5
5
5
Boiler efficiency
[%]
≤90
≤90
≤90
≤90
Single fuel load
[L]
200
200
200
200
Fuel
[-]
eco-pea coal
Power supply
-
~230V; 50Hz
Electrical power consumption during boiler work at
nominal power
[W]
230
230
230
230
Electric- power consumption (temporarily
maximum)
[W]
-
-
-
-
Temperature controller setting range
[°C]
60-85 (1 at a time)
Required chimney flue [pa]
[Pa]
20
20
23
30
Flue gas mass flow
[g/s]
10,4
14,16
16,5
20,62
Flow resistance δT [10k]
[mbar]
5,47
9,74
12,33
15,8
Flow resistance δT[20k]
[mbar]
1,36
2,43
3,80
4,3
Boiler weight
[kg]
345
370
427
460