Metacon-Next B.V.
RGS EI(1) 30 - EI(2) 60 - EW 240
12-07-2022
User Manual
art no: 89072 Rev: 1
17
Step 6a: Mounting of motor and tensioner (motor bracket)
Check that the limit switch housing is in the correct position: it should not touch the chain.
Mount the control box and connect it to the power supply including the battery (if supplied)
and the roll-down protection.
Attention: any other components may only be connected in step 10 of this manual!
Check that the direction of rotation corresponds to the knobs in the control box at the
connection to which the door is to be adjusted.
Place the sprocket wheel onto the motor shaft with the front side facing the motor.
The motor can now be mounted onto the tensioner with the corner strip, with the supplied
fasteners in the middle position of the tensioner’s (motor bracket) adjustment range.
Mount it against/onto the bracket.
Align sprocket wheels both horizontally and vertically, and secure them with the
locking screws.