background image

English

— 4 —

13.  CHECK DAMAGED PARTS AND AIR LEAK.

 

Before further use of the compressor, a guard or other 

part is damaged should be carefully checked to determine 

that it will operate properly and perform its intended 

function. Check for alignment of moving parts, binding of 

moving parts, breakage of parts, mounting, air leak, and 

any other conditions that may a

 ect its operation. A guard 

or other part that is damaged should be properly repaired 

or replaced by a metabo HPT authorized service center.

 

Have defective engine switch replaced by authorized 

service center. Have defective pilot valve replaced by 

authorized service center. Do not use compressor if 

engine switch does not turn it on and o

 .

14. NEVER USE COMPRESSOR FOR APPLICATIONS 

OTHER THAN THOSE SPECIFIED.

 

Never use compressor for applications other than those 

speci

fi

 ed in the Instruction Manual.

 

Never use compressed air for breathing or respiration.

15.  HANDLE COMPRESSOR CORRECTLY.

 

Operate the compressor according to the instructions 

provided herein. Never allow the compressor to be 

operated by children, individuals unfamiliar with its 

operation or unauthorized personnel.

  Carrying the compressor if tilted may result in fuel 

spillage.

16.  KEEP ALL SCREWS, BOLTS AND COVERS TIGHTLY 

IN PLACE.

  Keep all screws, bolts, and covers tightly mounted. 

Check their conditions periodically.

17. 

NEVER USE A COMPRESSOR WHICH IS 
DEFECTIVE OR OPERATING ABNORMALLY.

 

If the compressor appears to be operating unusually, 

making strange noises or vibration, or otherwise appears 

defective, stop using it immediately and arrange for 

repairs by a metabo HPT authorized service center.

18.  DO NOT WIPE PLASTIC PARTS WITH SOLVENT.

 

Solvents such as thinner, benzene, carbon tetrachloride, 

and alcohol may damage and crack plastic parts. Do not 

wipe them with such solvents. Wipe plastic parts with 

a soft cloth lightly dampened with soapy water and dry 

thoroughly.

19. USE ONLY GENUINE metabo HPT REPLACEMENT 

PARTS.

 

Replacement parts not manufactured by metabo HPT 

may void your warranty and can lead to malfunction and 

resulting injuries.

  Genuine metabo HPT parts are available from your 

dealer.

20.  DO NOT MODIFY THE COMPRESSOR.

 

Do not modify the compressor. Do not drill into, weld, 

patch or modify the air tanks. Do not make adjustments 

to the components that control tank pressure. Do not 

make alterations to the factory operating pressure 

settings. Do not operate at pressures or speeds in 

excess of the manufacturer’s recommendations. Always 

contact the  metabo HPT authorized service center for 

any repairs. Unauthorized modi

fi

 cation may not only 

impair the compressor performance but may also result 

in accidents or injury to repair personnel who do not 

have the required knowledge and technical expertise to 

perform the repair operations correctly.

21. TURN OFF THE ENGINE SWITCH WHEN THE 

COMPRESSOR IS NOT USED

 

When the compressor is not used, turn o

  the engine 

switch and open the drain valve to discharge the 

compressed air from the air tank.

22.  NEVER TOUCH HOT SURFACE

 

To reduce the risk of burns, do not touch tubes, heads, 

cylinder and mu

  er. Never allow any part of your body 

or other materials to contact with any exposed metal 

parts on this compressor. Never allow any part of your 

body to contact the mu

  er or adjacent areas.

 

These areas can remain hot for least 45 minutes after this 

compressor is shutdown. Cool down before servicing.

23.  DO NOT DIRECT AIR STREAM AT BODY.

 

Risk of injury, do not direct air stream at persons or 

animals.

24. DRAIN TANK

 

Risk of bursting. Water will condense in the air tank. If 

not drained, water will corrode and weaken the air tank, 

causing a risk of the air tank rupturing. Drain tank daily 

or after 4 hours of use. The drain contains moisture 

in the air, abrasion particles, rust, etc. To drain the air 

tank, open the valves slowly and tilt the compressor to 

empty accumulated water. Keep face and other body 

parts away from outlet of drain. Use ANSI Z87.1 safety 

glasses with side shields when draining, as debris can 

be kicked up into face.

25. 

MAKE SURE THE COMPRESSOR OUTLET 
PRESSURE IS SET LOWER THAN THE MAXIMUM 
OPERATING PRESSURE OF THE TOOL.

 

Too much air pressure causes a hazardous risk of bursting.

 

Check the manufacturer’s maximum pressure rating for 

air tools and accessories. The regulator outlet pressure 

must never exceed the maximum pressure rating.

26.  THE SAFETY VALVE MUST WORK PROPERLY.

 

Risk of bursting. Before starting the compressor, pull 

the ring on the safety valve to make sure that the safety 

valve operates smoothly. If the safety valve does not 

work properly, over-pressurization may occur, causing 

an air tank rupture or an explosion. Do not use the 

compressor if the safety valve is stuck or does not 

operate smoothly. Have the defective safety valve 

replaced by a metabo HPT authorized service center.

27. USE OF THIS PRODUCT WILL EXPOSE YOU 

TO CHEMICALS KNOWN TO THE STATE OF 
CALIFORNIA.

 

Some dust created by this product contains chemicals 

known to State of California to cause cancer, birth 

defects or other reproductive harm. Some examples of 

these chemicals are:

 

- compounds in fertilizers

 

- compounds in insecticides, herbicides and pesticides

 

- arsenic and chromium from chemically treated lumber

  To reduce your exposure to these chemicals, wear 

approved safety equipment such as dust masks that 

are specially designed to 

fi

 lter out microscopic particles. 

Use of this product will expose you to chemicals known 

to the State of California to cause cancer, birth defects 

and other reproductive harm. Avoid inhaling vapors 

and dust, and wash hands after using. This product 

contains chemicals, including lead, known to the State 

of California to cause cancer, and birth defects or other 

reproductive harm. Wash hands after handling.

00Book̲EC2610EA̲metabo.indb   4

00Book̲EC2610EA̲metabo.indb   4

2021/08/05   10:58:51

2021/08/05   10:58:51

Summary of Contents for EC 2610EA

Page 1: ...ne respectant pas les consignes de s curit peut entra ner la mort incendie et ou de graves blessures Ce manuel renferme des informations importantes relatives la s curit Veuillez lire attentivement t...

Page 2: ...gine exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm MEANINGS OF SYMBOLS Symbols The following show symbols used...

Page 3: ...on openings Do not place rags or other objects on or near these openings Risk of fire or explosion Do not carry and operate the compressor or any other electrical device near the spray area Do not use...

Page 4: ...ITCH WHEN THE COMPRESSOR IS NOT USED When the compressor is not used turn o the engine switch and open the drain valve to discharge the compressed air from the air tank 22 NEVER TOUCH HOT SURFACE To r...

Page 5: ...flammable articles and unauthorized people around this compressor 30 RELEASE THE PRESSURE WITHIN THE SYSTEM SLOWLY Dust and debris may be harmful 31 MAKE SURE THE HOSE IS FREE OF OBSTRUCTIONS OR SNAGS...

Page 6: ...lacement parts Repairs should be conducted only by a metabo HPT authorized service center SAVE THESE INSTRUCTIONS AND MAKE THEM AVAILABLE TO OTHER USERS OF THIS TOOL 00Book EC2610EA metabo indb 6 00Bo...

Page 7: ...filler plug Toggle Pilot valve unloader valve Pressure regulator knob Regulator pressure gauge Quick couplers Oil drain bolt Rubber foot Tank Drain valve Oil sight glass Handle Choke lever Fuel shut...

Page 8: ...ing the recoil rope assembly to start the engine ENGINE CHOKE Moving the choke lever completely to the left closed position will help start a cold engine After start up the choke lever must be moved c...

Page 9: ...s compressor CAUTION When operating or storing the compressor set 4 rubber foots downward on the floor Refer to Fig 1 Excessive vibration is a major cause of premature compressor failure Always mainta...

Page 10: ...from the system when this compressed air reaches a predetermined level The safety valve is preset by the manufacturer and must not be modified in any way Before starting the compressor pull the ring o...

Page 11: ...ore performing operation B When the toggle is in the ON position all air from this compressor is vented through the discharge mu er Fig 6 This gives an easy start feature For normal operation the togg...

Page 12: ...ee from obstructions Check this filter weekly 2 Adjustment of working pressure The air pressure coming from the air tank is controlled by the regulator knob Fig 8 Turn the pressure regulation knob clo...

Page 13: ...N Overfilling with oil will cause premature compressor failure Do not overfill 1 Within the first 50 hours of operation completely replace the oil of the pumping element Unfasten the oil drain bolt on...

Page 14: ...duit contient des substances chimiques signal es par l Etat de la Californie comme provoquant le cancer des d fauts cong nitaux et autres dommages aux organes de reproduction SIGNIFICATION DES SYMBOLE...

Page 15: ...t objet inutile fragments meubles etc 7 PRETEZ UNE ATTENTION PARTICULIERE AUX CONDITIONS ENVIRONNEMENTALES N exposez pas le compresseur la pluie Ne l utilisez dans des lieux humides ou mouill s La zon...

Page 16: ...ISEZ JAMAIS LE COMPRESSEUR S IL EST DEFECTEUX OU PRESENTE DES ANOMALIES DE FONCTIONNEMENT Si le compresseur fonctionne de fa on anormale produit des bruits inhabituels des vibrations ou para t d fectu...

Page 17: ...nces chimiques dont le plomb signal par l Etat de Californie comme provoquant le cancer des d fauts cong nitaux et autres dommages aux organes de reproduction Lavez vous les mains apr s manipulation 2...

Page 18: ...AC S PAR UN CENTRE DE SERVICE AUTORIS Le respect de cette r gle r duira le risque d incendie ou de blessures graves AVERTISSEMENT L utilisation d un compresseur peut provoquer la projection de corps t...

Page 19: ...Reniflard bouchon de remplissage d huile Commutateur Vanne pilote vanne de r glage Bouton du r gulateur de pression Manom tre du r gulateur Coupleurs rapides Boulon de vidange d huile Pied en caoutch...

Page 20: ...compresseur d air Le coupe circuit doit tre plac sur la position marche ON avant de tirer l ensemble de corde de recul pour d marrer le moteur STARTER DU MOTEUR D placer le levier de starter compl te...

Page 21: ...NT L UTILISATION 1 Positionnement AVERTISSEMENT Pour viter d endommager ce compresseur ne l inclinez pas transversalement ou longitudinalement de plus de 10 Placez ce compresseur au moins 4 pieds de t...

Page 22: ...3 Fixation du tuyau Ins rez le tuyau dans le coupleur rapide d j install sur le compresseur Fig 2 AVERTISSEMENT Ne pas fixer d outils l extr mit ouverte du tuyau avant que le d marrage soit termin Ser...

Page 23: ...cles sont en position et correctement install s TRANSPORT Eteignez l interrupteur du moteur avant de d placer le compresseur Transportez le compresseur correctement Maintenez le moteur plat lors du tr...

Page 24: ...es d une montre pour augmenter la pression d chappement et dans le sens contraire pour la diminuer Bouton du r gulateur de pression Coupleurs rapides Manom tre du r gulateur Fig 8 Le manom tre du r gu...

Page 25: ...que le compresseur refroidisse avant de commencer l entretien C Ouvrez toutes les vacuations D Enlevez le capuchon de la bougie 1 Nettoyage du filtre de la prise d air Ce filtre est con u pour nettoy...

Page 26: ...carburateur lorsque le compresseur n est pas utilis pendant plus de 30 jours En ce qui concerne le moteur suivez les instructions dans le manuel du moteur ASSISTANCE ET REPARATIONS Tous les compresseu...

Page 27: ...es ADVERTENCIA Los gases de escape del motor de este producto contienen sustancias qu micas que por lo que se sabe en el estado de California pueden provocar c ncer defectos cong nitos u otros da os a...

Page 28: ...vorecer el riesgo de lesiones Quitar de la zona de trabajo todos los instrumentos no necesarios residuos muebles etc 7 CUIDAR LAS CONDICIONES DEL LUGAR DE TRABAJO No exponer el compresor a la lluvia N...

Page 29: ...17 NO USAR NUNCA EL COMPRESOR SI PRESENTA DEFECTOS O IRREGULARIDADES EN SU FUNCIONAMIENTO Si el compresor funciona en modo anormal emite ruidos o vibraciones o presenta otro tipo de defectos interrump...

Page 30: ...oducto contiene sustancias qu micas incluso plomo que por lo que se sabe en el estado de California pueden provocar c ncer defectos cong nitos u otros da os al aparato reproductivo Lavarse las manos d...

Page 31: ...ESTE INSTRUMENTO 35 SIEMPRE DESCONECTE EL SUMINISTRO DE AIRE ANTES DE HACER CUALQUIER AJUSTE DE HACER EL MANTENIMIENTO DEL COMPRESOR O CUANDO ESTE NO SE ENCUENTRE EN USO 36 NO INTENTE JALAR NI MOVER...

Page 32: ...de corte de combustible C rter Man metro del dep sito V lvula de seguridad Cilindro Cabeza Filtro de la toma de aire Conmutador V lvula piloto v lvula de regulaci n Perilla reguladora de presi n Man...

Page 33: ...to y vida til para todo el sistema de compresor de aire El interruptor de parada se debe mover a la posici n ON antes de tirar del conjunto de la cuerda de retroceso para arrancar el motor CEBADOR DEL...

Page 34: ...e puede ocasionarle da os a la unidad ANTES DEL USO 1 Ubicaci n ADVERTENCIA Para evitar da ar el compresor no inclinarlo transversal o longitudinalmente m s de 10 Coloque este compresor al menos a 4 p...

Page 35: ...pe No encender nunca el motor en un garaje o zona cerrada 3 Conexi n de la manguera Introduzca la manguera en el acoplador r pido ya instalado en el compresor Fig 2 ADVERTENCIA No coloque ninguna herr...

Page 36: ...res de aire que no sean detergente E Controlar que todos los resguardos y las tapas se encuentren en posici n y correctamente instalados TRANSPORTE Apagar el interruptor del motor antes de mover el co...

Page 37: ...e vaciado y en sentido antihorario para disminuirla Perilla reguladora de presi n Acopladores r pidos Man metro regulador Fig 8 El man metro del regulador indica la presi n de aire disponible en el la...

Page 38: ...comenzar a realizar el mantenimiento C O Abrir todas las salidas D Saque el capuch n de la buj a 1 Limpieza del filtro de la toma de aire Este filtro ha sido dise ado para limpiar el aire que entra en...

Page 39: ...carburante y el carburador cuando el compresor no est en uso m s de 30 d as En relaci n al motor siga las instrucciones del manual del motor ASISTENCIA Y REPARACIONES Todos los compresores de calidad...

Page 40: ...wer A 15 1 Konan 2 chome Minato ku Tokyo 108 6020 Japan Distributed by 1111 Broadway Ave Braselton Georgia 30517 3405 American Drive Units 9 10 Mississauga ON L4V 1T6 00Book EC2610EA metabo indb 40 00...

Reviews: