13
Repairs and modifications to the tank are not permitted.
The effect of the safety valve must not be bypassed or made inoperative.
Contact between spraying device materials and hydrogen peroxide or other agents
that give off oxygen may result in increased pressure similar in nature to an
explosion. Never place such agents in the device.
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
Do not allow the device to remain under pressure and/or exposed directly to
sunlight. Make certain the device is not heated beyond the maximum operating
temperature
(
→
Table 1 below).
Never blow through the nozzles or valves with your mouth.
Use only MESTO spare and accessory parts.
We cannot assume any liability resulting from the use of third-party parts.
Wear suitable protective equipment when working with hazardous substances.
When pumping, always observe the pressure gauge to ensure the maximum
spraying pressure is not exceeded
(
→
Table 1 below)
.
Before filling, after use and before maintenance work, allow the residual pressure in
the tank to dissipate completely
(
→
Section "After Use", Section 1)
.
Scope of delivery
Tank [1], with pump [2] and spare parts pouch [3], spray line [4], instructions for use [5],
carrying strap [6], spray lance [7], pump holder [8]
(Figures 1a and 1b)
You will find the illustrations referred to above in the front fold-out pages 3 – 5 of these
Instructions for Use.
Technical data
Device family
FERROX
INOX
Type
3565
3585
3595
3615
Max. filling amount
5 l
10 l
5 l
10 l
Total contents
9 l
13 l
9 l
13 l
Max. spraying pressure
6 bar (87 psi)
Max. operating
temperature
50 °C (104 °F)
Weight when empty
4,7 kg
5,2 kg
4,2 kg
4,7 kg
Material of tank
Steel with polyester coating
Stainless steel
Where device is carried
Shoulder
Back
Shoulder
Back
Technical residual
quantity
0,03 l
Max. volume flow
4,5 l/min
Recoil force
< 5 N
Table 1