17
Fault
Cause
Remedy
Liquid flows out of the
pump.
Valve disk [26] dirty of
defective.
Clean or replace the valve disk.
(Fig. 20).
The nozzle does not
spray even though
pressure is present.
Filter [25]
and / or nozzle [23]
blocked.
Clean the filter or / and nozzle.
(Fig. 18 +19).
Only a spray, emerges,
there is no atomization.
Insert [24] is missing
Position the insert in the
nozzle.
(Fig. 18).
safety valves blows off
too early.
Safety valve [12] is defective.
Replace safety valve.
(Fig. 22).
The shut-off valve does
not close.
Liquid emerges without
the lever being activated.
O-ring [27] on the pressure bolt
not greased.
Defective pressure bolt [28] or
O-ring [27]
Grease the O-ring of the
pressure bolt.
(Fig. 23).
Replace the pressure bolt or
O-ring.
(Fig. 23).
Pressure gage is not
indicating any tank
pressure.
Pressure gage [16] defective. Sever attachments (at top, at
bottom, on right) [29].
(Fig. 24)
Open panel [30], unscrew
pressure gage [16] with wrench
and replace.
(Fig. 24).
Insert fixing knob [31] (from the
spare parts pouch [3]), push to
the right and insert panel [30].
(Fig. 25).
Contact address for additional information
→
see title page
.
Warranty
We guarantee that from the time it is first purchased for a period of the legally valid required
warranty period (maximum 3 years) this device will not exhibit any material or processing
errors. If defects are discovered during the warranty period, MESTO or the distributor in
your country will repair the device without charging for the labor or material or (at the
discretion of MESTO) replace the device itself or its defective parts.
If such defects are discovered, please contact us immediately. We require the invoice or
cash register receipt for purchase of the device.
The warranty does not include wearing parts (seals, O-rings, diaphragm, etc.) or defects
which have occurred due to improper use or unforeseeable circumstances.