Mesalabs IBP HDM97Pocket Series Safety Instructions And Quick Start Manual Download Page 5

HDM97Pocket Quick Reference

 

 

\\

  

5

www.ibpmedical.com

Then                                    to apply and save setting,
or   

      to  discard this setting.

TIMER

OK

OK

ESC

ON
OFF

stopwatch function enabled
stopwatch function disabled

Then                              to apply and save setting,
or   

      to discard this setting.

PHT

OK

Pressure Hold Test

increases the value
lowers the value

OK

ESC

Then                              to apply and save setting,
or   

      to discard this setting.

pH

OK

Only available with version BP

ON
OFF

pH enabled
pH enabled

OK

ESC

Then                              to apply and save setting,
or   

      to  discard this setting.

FLOW

OK

Only availble with version BQ

ON
OFF

FLOW enabled
FLOW disabled

OK

ESC

Then                             to apply and save setting,
or   

      to  discard this setting.

TEMP

OK

Only availble with version BN, BO, BP and BQ

ON
OFF

sole readout of temperature enabled
sole readout of temperature disabled

OK

ESC

PR H-RES

OK

Only availble with version BM, BH, BO, BP and BQ

ON
OFF

sole readout of temperature 
enabled

OK

ESC

Attention: The higher resolution does not give a higher measuring accuracy.

EXIT

OK

A save dialog will appear, if changes have been made.

ON
OFF

OK

ESC

SAVE

to apply and save all settings by exiting
to discard all settings by exiting

Summary of Contents for IBP HDM97Pocket Series

Page 1: ...M97BO HDM97BP HDM97BQ This document describes the major functions of the HDM97Pocket instrument series The complete manual can be found at http www ibpmt com medical_e meter_documents shtm and on the...

Page 2: ...tic discharge on the connectors This can lead to substantial damage of the instrument Make sure to be completely discharged before touching the connectors or cables connected to the instrument Adjust...

Page 3: ...USB connector is mounted on the right side of the instrument It is implemented as a Mini USB A receptacle The current consumption of the HDM97Pocket all versions can be up to 500 mA while charging the...

Page 4: ...P BQ Target time adjustment for pressure holt test PHT TIMER All Enables disables the stopwatch function Flow BL BQ Enables disables the Flow channel pH BP enables disables the pH channel TEMP BN BO B...

Page 5: ...and save setting or to discard this setting FLOW OK Only availble with version BQ ON OFF FLOW enabled FLOW disabled OK ESC Then to apply and save setting or to discard this setting TEMP OK Only avail...

Page 6: ...alue Reset of both the min And max Value Return to measuring mode ESC F F Channel Select No function TEMP F Available in versions bn bo bp and bq if enabled in the basic settings Selection between uni...

Page 7: ...x Value ESC Return to measuring display Reset accumulated volume to 0 Timer If enabled in the Basic Settings OK OK OK Afterwards Afterwards Timer Timer Timer The cycle start stop and reset can start a...

Page 8: ...n pass off through the outlet For immersion usage the probe must be unscrewed from the flow through adapter To accomplish that do not turn the upper shank the probe may be damaged Only turn the nut as...

Reviews: