 Chapter 4: Binary inputs

4.2

 

Binary inputs, 4-gang

 Binary input REG-K/4x24

Art. no. 644892

Binary input REG-K/4x24Chapter 4:Binary inputsArt. no.644892As at 09/074.2Binary inputs, 4-gang

1.

Function  

1

2.

Operating and display elements 

 1

3.

Installation  

1

4.

Technical Data 

 2

5.

Settings in the EIB-Tool-Software (ETS) 

 2

6.

Application overview 

 2

6.0.1 Multi-function.counter 12BA/1.0 

 3

The Merten binary input REG-K/4x24 is used to con-
nect conventional 24 V devices (such as door and win-
dow contacts) to the KNX bus.

½

Caution: 
High voltages can cause damage.

½

Risk of fatal injury:
All work carried out on the unit may only be per-
formed by skilled electricians. Observe the re-
gulations valid in the country of use, as well as 
the valid KNX guidelines.

½

Caution: All the devices that are installed next to 
the binary input must be equipped with basic in-
sulation at the very least.

¼

Risk of fatal injury from electrical current.
During installation, the safety regulations speci-
fied in DIN VDE 0105 must be observed. The de-
vice may only be installed by skilled electricians. 
Otherwise, there is a risk of fire or electrocution

½

Caution: If there are any 230 V cables in the vi-
cinity, make sure that the distances to them 
specified in the applicable standards and regula-
tions are maintained. The cover of the bus con-
necting terminal must always be mounted.

1

Snap onto a 35 x 7.5 mm DIN profile rail which con-
forms to standard DIN EN 50022. 

2

Connect the bus plug and attach the cover of the 
bus connecting terminal.

3

Connect the input cables (see figure connection 
example)

When the bus voltage is connected and there is a sig-
nal at the input, the corresponding yellow channel sta-
tus display will light up

|

The 0 V conductors must be connected to the 
device. Inputs E1 to E4 have a common poten-
tial (4 x 0 V).

½

Caution: The connection of the potentials inside 
the device for binary input REG-K/4x24 is not 
suitable for transferring load currents.

Binary input REG-K/4x24

Artikel-Nr.

644892

Inhaltsverzeichnis

1. Function

2. Operating and display elements

A

Cover of the bus connecting terminal

B

Programming button/programming display

C

Operating display

D

Channel status displays

644492

E 4

E 2

RUN

E 1

E 3

Binäreingang REG-K/4x10
binary input REG-K/4x10

E 4

E 2

E 1

E 3 0V

0V

E1  0V  E2       E3   0V  E4    

Binäreingang

Binäreingang

AC 230V

AC 230V

REG-K/4x230

REG-K/4x230

E 4

E 2

RUN

E 1

E 3

A

B

C

D

3. Installation

KNX

+ -

b

us coupler

24V
AC/DC

0V

E2

E3

E4

+

+

+

E1

+

-

-

Summary of Contents for REG-K/4x24

Page 1: ...on Caution If there are any 230 V cables in the vi cinity make sure that the distances to them specified in the applicable standards and regula tions are maintained The cover of the bus con necting te...

Page 2: ...is designed for use at an installation height of up to 2000 m above sea level MSL Connections Inputs outputs Screw terminals Single core 1 5 mm to 2 5 mm Finely stranded with connector sleeve 1 5 mm t...

Page 3: ...ent is possible for the parameter setting selected Operating mode For the input functions you can select between the Make contact and Break contact operating modes Additional startup delay of the appl...

Page 4: ...briefly will switch the light on and vice versa and if the light has been dimmed up prolonged activation of the key will dim the light down again On release after prolonged activation a stop telegram...

Page 5: ...ions Blind control function up or down with one key in each case dual surface blind operation After the corresponding key is pressed for a short ti me a stop step telegram will be transmitted after th...

Page 6: ...it one or two objects simultaneously and select the size of the objects required 1 bit 2 bit priority control 4 bit or 1 byte in steps or infinitely as needed This enables you to parameterise a large...

Page 7: ...ect A B Object A B Action on activation Action on release only with 2 bit and 4 bit priority control value 1 value 2 only with 1 byte in steps 0 100 value 1 value 2 only with 1 byte infinitely 0 255 v...

Page 8: ...value is transmitted immediately and a new cycle time is started If a cycle time is already running this is not interrupted the toggled value is transmitted after the current cycle time has elapsed a...

Page 9: ...cle time e g 6 minu tes Number of objects 2 object A B Object A B 1 bit Object A Action on release before the long activation time has elapsed transmits 1 After a cycle time has elapsed here 3 minutes...

Page 10: ...ush button action stops the toggling and transmits a scene to retrieve the scene use the scene module for the actuator which has been activa ted which switches off everything Number of objects 2 objec...

Page 11: ...ly with extended pulse edge function Detection of a long activation time from 100 ms Factor 4 250 Action when activated Action on release only with extended pulse edge function Action on release befor...

Page 12: ...ack again The limit values are approached by one step interval at a time When a limit is reached the slide direction is reversed for the next action none stops cyclical transmission No action is carri...

Page 13: ...g can be read off by setting the read flag Ensure that the counter reading is not overwrit ten via the bus write flag Additionally you have the option of transmitting the counter reading cyclically af...

Page 14: ...for each input 2 All inputs function as a master input You can determine whether a disable object 0 or 1 should be blocked Separately for each input You can use this function to block each of the four...

Page 15: ...disable function is activated via the disable object all current push button functions are reset or interrupted Behaviour on application recovery of the bus vol tage When a bus voltage is applied or...

Page 16: ...B 1 bit 1 byte in steps 0 100 1 byte infinitely 0 255 Value ON telegram OFF telegram Value 100 adjustable in steps of ten as well as 25 and 75 Value 0 255 255 default setting Input X Parameter Setting...

Page 17: ...ts one two Object A B 1 bit 2 bit priority control 1 byte in steps 0 100 1 byte infinitely 0 255 Action when activated only with 1 bit transmits 1 only with 1 bit transmits 0 only with 2 bit 1 byte tr...

Page 18: ...ly only with 1 bit transmits 1 immediately and af ter a cycle time of 0 only with 2 bit 1 byte transmits value 1 and after a cy cle time value 2 only with 1 byte increase the current object va lue by...

Page 19: ...ge in brackets different values between 0 01 and 327 68 in different step intervals 0 01 0 to 20 47 default setting value 1 2 32768 32767 32768 32767 value 1 2 0 65535 0 65535 Input X Parameter Settin...

Page 20: ...nsmis sion no change Scene address 1 0 63 Scene address 2 0 63 0 63 in single steps Scene address 1 is designed to Scene address 2 is designed to retrieve the scene set by de fault to value 1 store sc...

Page 21: ...y value 1 value 2 0 100 in 10 steps 100 default setting value 1 0 default setting value 2 value 1 value 2 0 255 255 default setting value 1 0 default setting value 2 Base for cyclic interval 0 1 secon...

Reviews: